A comparative study of accuracy of linear measurements using cone beam and multi-slice computed tomographies for evaluation of mandibular canal location in dry mandibles

Asieh Zamani Naser, Bahar Behdad Mehr

Abstract


Background: Cross- sectional tomograms have been used for optimal pre-operative planning of dental implant placement. The aim of the present study was to assess the accuracy of Cone Beam Computed Tomography (CBCT) measurements of specifi c distances around the mandibular canal by comparing them to those obtained from Multi-Slice Computed Tomography (MSCT) images.

Materials and Methods: Ten hemi-mandible specimens were examined using CBCT and MSCT. Before imaging, wires were placed at 7 locations between the anterior margin of the third molar and the anterior margin of the second premolar as reference points. Following distances were measured by two observers on each cross-sectional CBCT and MSCT image: Mandibular Width (W), Length (L), Upper Distance (UD), Lower Distance (LD), Buccal Distance (BD), and Lingual Distance (LID). The obtained data were evaluated using SPSS software, applying paired t-test and intra-class correlation coeffi cient (ICC).

Results: There was a signifi cant difference between the values obtained by MSCT and CBCT measurement for all areas such as H, W, UD, LD, BD, and LID, (P < 0.001), with a difference less than 1 mm. The ICC for all distances by both techniques, measured by a single observer with a one week interval and between 2 observers was 99% and 98%, respectively. Comparing the obtained data of both techniques indicates that the difference between two techniques is 2.17% relative to MSCT.

Conclusion: The results of this study showed that there is signifi cant difference between measurements obtained by CBCT and MSCT. However, the difference is not clinically signifi cant.

Key Words: Cone beam computed tomography linear measurements, multi-slice computed


Full Text:

PDF

Refbacks

  • There are currently no refbacks.