This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
The heat from laser can lead to the destruction of organic components of enamel and consequently changes in the mechanical properties of enamel. The purpose of this study was to evaluate the effect of diode laser on the nanomechanical properties of enamel in the process of debonding the ceramic brackets.
In This in vitro study Eighteen ceramic brackets were bonded on the intact premolars in 3 groups of 6 (one control and two study groups). To debond the brackets in the study groups, laser diode was used for 3 s with 1W and 3W power. Shear bond strength and adhesive remnant index were recorded for all groups. Hardness and elastic modulus were measured in 1–31 μ depth from enamel surface in each debonded area. Analysis of variance was used for determining the difference in shear bond strength (SBS), hardness, and elastic modulus and was followed by post hoc Tukey's honest significant difference test. One-sample t-test was used to compare the changes in the pulp temperature with the standard threshold (5.5°C). The significance level was set at %5 in this study.
SBS was significantly greater in the control group compared to the study groups. There was no significant difference in the average of hardness and elastic modulus of enamel between the groups. Pulp temperature elevation in the study groups was significantly < 5.5°C (P = 0.000).
The diode laser with either 1W or 3W power for 3 s is effective in debonding the ceramic brackets without any detrimental effect on the pulp or mechanical properties of enamel. In regard to the pulp health, the 1W power laser is rather recommended for debonding the ceramic brackets than the 3W laser power.
Ceramic brackets are one of the best choices for patients and the most acceptable appliances in orthodontics.
Laser softens the adhesive by increasing the temperature in brackets and teeth.
This in vitro study was done in Oral and Dental Diseases Research Center in Kerman University of Medical Sciences and Central Laboratory of Isfahan University of technology. In this study, 12 healthy maxillary premolars extracted for the orthodontic treatment purposes were used. The number of samples was specified based on previous studies. Selection criteria included no decalcification or cracking of the enamel surface. After cleaning the roots, teeth were saved in a balanced saline solution of HANK (Gibco, Life Technologies, USA) to reduce demineralization.
Bonding of brackets
The buccal surface of the crown of each tooth was then divided to mesial and distal sides by a hypothetical center line. Eighteen monocrystalline ceramic brackets (Radiance, American orthodontics, USA) were bonded randomly on mesial or distal sides (6 sides, either mesial or distal, remained free) by curing a transbond XT composite resin (Transbond XT, 3M Unitek, Monrovia, California, USA) with LED (Demi, kerr Co., USA) for 40 s (10 s for each side of bracket)
Bonded brackets on buccal surface.
Shear bond strength test and Adhesive Remnant Index test for control group
The teeth were placed in testometric machine (10KN, M350-10CT, Testometric, England) so that the bracket's slot was horizontal. In control group, a sharp Chisel blade was placed at the enamel/bracket's base interface and the machine was set at the speed of 0.5 mm/min. The debonding force was measured in terms of Newton and converted to mega Pascal unit (MPa) through dividing the force by the area of bracket's base. After debonding, the enamel surfaces and the brackets' base were examined by stereomicroscope (ST30B2 L, Motic, Spain) with ×10 and they were rated based on the amount of adhesive remaining on the enamel surface and Adhesive Remnant Index (ARI) criterion.
ARI scoring from 0 to 3 is as follow:
Zero: No adhesive left on the surface and the bond break occurred between the adhesive and enamel.
Less than half of adhesive left on the tooth surface At least, half of the adhesive left on the tooth surface All of the adhesive left on the tooth surface and the bond break occurred between the adhesive and the bracket's base.
Shear bond strength test, Adhesive Remnant Index test, and the pulp temperature changes in the study groups
Following placing a K-type thermocouple inside the pulp chamber of the teeth, brackets of test groups were subject to either 1 Watt (1W group) or 3 Watt (3W group) power. Diode laser (Diode 940 nm, Epic 10, Biolase, CA, USA) irradiation was applied directly to the center of bracket for 3 s
Fixed sample on testometric machine accompanied with laser and thermocouple.
The nanoindentation test
The nanoindentation test was done by CSM indentation tester (Nano-Hardness Tester, CSM, Switzerland) with maximum load of 10 mN by a diamond Berkovich indenter tip. Each test consisted of three parts: 10 s loading up to a maximum amount, 1 s holding in the maximum load, and 10 s for unloading. In this study, our indentation was done in the depth of 1–31 μ from the enamel surface (7 points at intervals of 5 μ) in all surfaces from which the bracket was debonded.
Statistical analysis
To analyze the data and obtain the results, the SPSS spreadsheet (SPSS Inc., Chicago, IL, USA) was used. The significance level was set at %5 in this study. The ARI, shear bond strength (SBS), changes in pulp temperature, hardness, and elastic modulus data were tested for normal distribution by Kolmogorov–Smirnov that they were normally distributed in this study. The mean value for SBS, hardness, and elastic modulus for all groups were compared with one-way ANOVA and was followed by Post hoc Tukey's honest significant difference test. Chi-square test was used to compare the ARI percentage in different groups.
One-sample t-test was used to compare the changes in pulp temperature in groups with the standard threshold of 5.5°C and independent t-test was used to compare the relative pulp temperature changes between groups
Descriptive data for SBS are shown in
Statistical analysis showed no significant difference for the mean value of hardness (P = 0.482) and elastic modulus (P = 0.472) between any of the groups (control, 1W, and 3W). Results can be seen in
Mean value of hardness at different distance from enamel surface. Mean value of elastic modulus at different distance from enamel surface.
Radiating diode laser with either power of 1W or 3W for 3 s elevated the pulp temperature, but it was significantly <5.5° (P = 0.000). Also comparing pulp temperature changes between the two test groups (1W laser and 3W laser) showed a significant difference (P = 0.000) in such a way that the amount of temperature elevation in the group of 1W laser (0.6 ± 0.16) was significantly less than the group of 3W laser (2.35 ± 0.76)
According to this study, the laser diode with either 1W or 3W power for 3 s is effective in reducing bond strength and consequently in debonding the ceramic brackets without any detrimental effect on the pulp or mechanical properties of enamel.
Previous studies have shown that lasers can be effective in reducing the debonding force of ceramic brackets.
Similar results have been reported by Almohaimeed and Halim. In their study, precoated brackets (APC plus APCII) and laser with 3W power for 3 s were used. They stated that a laser with 3W power for 3 s is effective in debonding the ceramic bracket.
Yassaei et al. used diode laser with 2.5W power for 10 s in debonding the polycrystalline ceramic bracket and stated that using this laser reduces the risk of damage to the enamel such as crack.
In this study, diode laser with 1W power (in addition to 3W) for 3 s was used for debonding the ceramic which is the minimum power and energy used in similar studies. Although the debonding force for radiance bracket, when using diode laser with 1W power, is higher than 3W power, but this difference is not statistically significant, and it seems that diode laser with 1W power in debonding the ceramic bracket is effective as much as the 3W power is.
Comparing the ARI score between the groups (control, 1W laser, and 3W laser) showed no significant difference between the groups. This finding is consistent with the studies of Yassaei et al. and Feldon et al. but it was in contrast with the results obtained from the study of Almohaimeed et al. which showed that the laser diode increased the ARI Score
In this study, although there was no significant difference between the groups regarding the ARI Score, but the ARI Score 3 was the most frequent. This finding is consistent with the studies of Romano et al. and Fernandez and Canut who showed the highest bond failure at the adhesive/bracket interface.
In this study, the mean of pulp temperature elevation in test groups was compared with the results of Zach and Cohen's study. Their study revealed that if the pulp temperature elevates for more than 5.5°C, 15% of the sample teeth will show necrosis.
In our study, the pulp temperature elevation after laser radiation for 3 s, with either 1W or 3W power, was significantly <5.5°C which was consistent with the studies of Yassaei et al. and Feldon et al.
These results can be attributed to this fact that the absorption coefficient of diode laser in enamel is low; thus, the surface energy increases and decreases quickly during and after laser exposure, respectively, and leaves no detrimental effect on the pulp.
In this study, there was no significant difference in the mean of hardness and elastic modulus between the groups and between layers. Although the enamel hardness in the groups irradiated with laser was slightly increased compared to control group, it was not statistically significant.
Iijima et al. examined the effect of CO
2laser in debonding the ceramic bracket on the mechanical properties of the enamel. The results showed that the hardness and elastic modulus of enamel were not affected by CO
2laser irradiation
Iijima et al. examined the effect of debonding the bracket on nanomechanical properties of the enamel using self-etch and conventional-etch adhesives. They showed that in conventional etch group, the superficial 1 and 5 μ thick layers had significant lower hardness and elastic modulus than deeper layers.
According to these studies, it seems that the reduced hardness and elastic modulus in the superficial 1 μ thick layer in our study was also because of using the conventional etch for bonding the brackets.
Alavi et al. examined the effect of bonding the bracket by Er: YAG laser on the nanomechanical properties of the enamel. The results showed that the enamel hardness of superficial 1–21 μ thick layers and elastic modulus of superficial 1–6 μ thick layers in the Er: YAG laser group were significantly higher than the conventional etch and control groups (intact enamel) which could be associated with the changes resulted from the Er: YAG laser on the enamel surface.
Dental enamel contains 85%–95% hydroxyapatite crystals, 8%–12% water, and 2%–3% organic components. Hardness and elastic modulus are different for each tooth because mechanical properties vary according to the mineral content of the enamel, age, and the individual health. These values also vary based on the location (distance from the enamel surface), the magnitude of force, indenter type, organic components, and the direction of enamel rods. These factors may explain the differences in the studies.
The results of this study show that the use of diode laser in ceramic bracket debonding has no significant effect on the mechanical characteristics of the enamel surface such as hardness and elastic modulus. This was, however, an in vitro study and the results may, therefore, be unlike the results of clinical studies. It is also recommended that to evaluate the efficiency of diode laser with 1W power for 3 s which is the lowest energy used in the studies so far, some studies with larger sample sizes may be beneficial.
Diode laser with 3W and 1W power for 3 s is effective in reducing the bond strength of monocrystalline ceramic bracket It seems that the diode laser with 1W power for 3 s can be effective in debonding the monocrystalline ceramic bracket The heat resulted from the diode laser, whether with 3W or 1W power for 3 s, has no destructive effect on the pulp and 1W laser is safer than 3W laser for the pulp Diode laser with 1W and 3W power does not make significant change in the nanomechanical properties of the enamel; therefore, under the conditions of this study, diode laser with 1W power is recommended for debonding the monocrystalline ceramic bracket.
Acknowledgment
We would like to thank Mrs. Maryam hassanzadeh for contributing in conducting research.
Financial support and sponsorship
Nil.
Conflicts of interest
The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or nonfinancial in this article.