This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Background:
The aim of this in vitro study was to compare the film thickness and antibacterial properties of mineral trioxide aggregate-propylene glycol (MTA-PG) as a sealer in comparison with MTA Fillapex and AH26 sealers.
Materials and Methods:
In these in vitro study the antibacterial property of the sealers was evaluated using direct contact test in fresh and set states. Enterococcus faecalis was incubated in direct contact with fresh and set materials. The growth of exposed bacteria was evaluated by counting colony-forming units (CFUs) after 10 min and 1 h in the culture medium. The film thickness of sealers was measured according to the International Standard Organization 6876/2012. The data were statistically analyzed using an independent t-test and repeated measures of ANOVA. The level of significance was set at 0.05.
Results:
CFU means in AH26 was significantly more than other groups (P < 0.0001), but there was no difference between MTA-PG and MTA Fillapex. The mean of CFUs in set AH26 after 1 h exposure was significantly >10-min exposure (P = 0.006). The mean film thickness values of MTA Fillapex, MTA-PG, and AH26 were 57.3, 50.9, and 78.3 μm, respectively.
Conclusion:
MTA-Fillapex and MTA-PG showed distinct antibacterial effect. AH26 showed more antibacterial effect in fresh state in comparison with set state. The film thickness of MTA-PG and MTA-Fillapex was significantly less than AH26.
The quality of root canal therapy has been improved by providing sealers and obturation materials with high sealing ability and biocompatibility. Mineral trioxide aggregate (MTA) as a biomaterial has several applications in endodontics because of various desirable characteristics including high biocompatibility and low cytotoxicity,
1release of calcium hydroxide (Ca(OH)
2),
2sealing ability against the bacteria and saliva,
3antibacterial features,
4ability of setting in the presence of bleeding or in wet condition,
5adequate compressive strength, and acceptable hardness.
4However, inappropriate consistency and difficult handling are the two main drawbacks of MTA.
5The efforts have been made to improve these properties, including adding propylene glycol (PG) to MTA to enhance its manipulation.
6,
7,
8PG (1,2-propanediol) is a dihydric alcohol without toxicity, carcinogenicity, or genotoxicity and has been used as a solvent in several drug mixtures and food products.
9Studies have been shown that mixing MTA with PG could improve its flow and pushout bond strength in addition to increasing the pH of dentin and cementum due to enhanced release of Ca(OH)
2,
9,
10without affecting its desirable biocompatibility.
7Since adding PG to MTA results in better consistency and manipulation, this mixture may also be used as a sealer. Recently, a new generation of sealers with calcium silicate base has been introduced.
11,
12Due to the similarity in composition to MTA, these sealers are sometimes called MTA-based sealers. Despite favorable properties of MTA-based sealers such as MTA-Fillapex, they have shown some drawbacks such as higher cytotoxicity and lower sealing ability in comparison to resin-based sealers.
13,
14Furthermore, some studies reported lower biocompatibility of MTA-Fillapex than MTA.
15Moreover, although MTA-Fillapex has shown antibacterial and antibiofilm properties in short terms,
16,
17its effect after setting was insignificant.
17These drawbacks have been attributed to the low percentage of MTA in the sealer composition and presence of resin and other additives.
13,
14Remained microorganisms in the root canal system have the potential to survive despite chemomechanical preparations. Therefore, root canal filling materials such as sealers should have immediate and ideally long-term antibacterial property to remove these microorganisms.
17The antibacterial characteristic of MTA-PG has not been studied, and therefore, the main goal of this study was to evaluate the antibacterial property of MTA-PG as a sealer in comparison with two commonly used resin-(AH26) and MTA-based (MTA Fillapex) sealers. Meanwhile, another property of ideal sealer is its penetration ability between the gutta-percha cones and into the root canal irregularities. This ability depends on the flow and viscosity of sealer.
18The American Dental Association has not introduced any criterion for direct measurement of viscosity; however, film thickness has been proposed as an indirect criterion for assessing viscosity. Since the film thickness of MTA-PG sealer is unknown, the second goal of the present study was to compare the film thickness of MTA-PG, AH26, and MTA Fillapex sealers.
Materials and Methods
This in vitro study was approved by the Research and Ethics Committee of Tabriz University of Medical Sciences (Tbzmed.REC.1394.604). In thisin vitro study, standard suspension of Enterococcus faecalis (ATCC 29212, Reference Laboratories of Iran Research Center, Tehran, Iran) was used, and antibacterial assessment was carried out by direct contact test (DCT). In this method, the bacteria were kept in direct contact with testing materials, and then, growth of the bacteria was evaluated.
19,
20
Antibacterial properties of materials in the fresh condition
In this study, eight microtubes with the volume of 1.5 ml were used for each of the following testing materials prepared under aseptic conditions: AH26 sealer and MTA Fillapex (Angelus, Londrina, Brazil) were prepared according to the manufacturer's orders. In addition, MTA-PG sealer was prepared by mixing MTA (Angelus, Londrina, Brazil), with 50% PG (Merck, Germany) and 50% distilled water (DW). The DW/PG ratio was determined by volume, and the powder/liquid ratio was the same for MTA-PG groups (1 g powder to 0.33 mL liquid). The floor and one-fourth of the inner walls of each microtube were covered by the prepared sealers, and after 20 min, 10 μL of 0.5 McFarland standard suspension of E. faecalis prepared at the sterile Brain–Heart Infusion Broth (BHI-Oxid LTD, Hanks, USA) was added to microtubes. Then, the microtubes were incubated at 37°C for 1 h. In this way, the evaporation of suspension liquid could guarantee the direct contact. After that, the sealers in the microtubes were immersed in 500 μL of BHI broth, and after stirring for 2 min, they were incubated at 37°C. Finally, after incubation for 10 min and 1 h, 10 μL of solutions existing in each microtube was separately transferred to the BHI agar culture mediums, and after incubation for 24 h, bacterial colony count was done for each plate. Some of the samples were diluted up to 100 times to enable counting. In the negative control group (n = 3), no material was placed in microtubes and bacterial suspension was not added. Although, in the positive control group (n = 3), no material was placed in the microtubes, bacterial suspension was added to microtubes.
Antibacterial properties of materials in the set condition
The preparation procedures were exactly the same as the fresh condition. However, in this condition, bacterial suspension was placed on the testing materials after 72 h.
20
Film thickness assessment
The film thickness assessment was carried out according to the International Standard Organization (ISO) 6876/2012 instruction. Two flat glass plates with 5-mm thickness and 200 ± 10-mm surface area were placed on each other, and the total thickness was measured by a digital micrometer to the nearest 10 μm. AH26 sealer and MTA Fillapex (Angelus, Londrina, Brazil) were prepared according to the manufacturers' orders, and MTA-PG sealer was prepared by mixing MTA (Angelus, Londrina, Brazil), with 50% PG (Merck, Germany) and 50% DW. The DW/PG ratio was determined by volume, and the powder/liquid ratio was the same for MTA-PG groups (1 g powder to 0.33 mL liquid). Immediately after mixing, 0.5 ml of each sealer was transferred onto the first plate and the second plate was placed over it. After 180 ± 5 s, the force of 150 N was applied vertically on the upper plate. The total thickness of the plates and the sealer between them was measured using micrometer after 10 min from the mixing time (7 min from the time of applying the force). The total thickness of the plates was deducted from this amount and the film thickness of the sealer was obtained. The test was repeated for three times for each sealer, and the mean value was recorded as film thickness of that sealer.
Statistical analysis
Statistical analysis was performed using SPSS software (SPSS version 20.0, SPSS, Chicago, IL, USA). The data were statistically analyzed using repeated measures of ANOVA. Two independent sample t-tests were used to compare the colony-forming unit (CFU) amounts in each group at two different times (10 min and 1 h). The level of significance (P) was set at 0.05.
Results
The means and standard deviations of CFUs of E. faecalis related to each endodontic sealer in fresh and set conditions are presented in
Table 1. The controls confirmed the validity of experimental procedures, as no bacterial growth was seen in negative control and bacterial growth occurred in the positive control. There was a significant difference of mean CFU among the groups (P < 0.001). The results of Tukey's post hoc test showed that CFU means in AH26 was significantly more than other groups (P < 0.0001), but there was no difference between the CFU means of MTA-PG and MTA-Fillapex. There was a significant difference between the two-time evaluations in AH26 group. The mean of CFUs in set AH26 after 1 h exposure was significantly >10-min exposure (P = 0.006). The mean film thickness values of MTA-Fillapex, MTA-PG, and AH26 were 57.3, 50.9, and 78.3 μm, respectively. The film thickness of MTA-PG and MTA-Fillapex was significantly less than AH26.{Table 1}
Discussion
In this study, the antibacterial characteristic of MTA-PG as a sealer was compared with two common resin-based (AH26) and MTA-based (MTA-Fillapex) sealers in fresh and set conditions. Furthermore, the film thickness of MTA-PG as a sealer was compared with MTA-Fillapex and AH26 sealers. In the present study, DCT was used to assess the antibacterial properties of the sealers. Other methods such as agar-diffusion test (ADT) have also been used with some major drawbacks.
21There may be chemical interactions between media and testing materials, and there is no study definitely correlating the inhibition zone diameters in ADT with clinical performance of disinfectants. The antibacterial effect of some sealers is related to their pH. Therefore, the buffering effect of agar has a vital role in determination of diameter of inhibition zone.
21However, DCT is a repeatable and quantitative method which is widely used for the evaluation of antibacterial effect of sealers and root-end filling materials since direct contact of bacteria with the sealers is obtained in this method.
20,
22The data from this method are related to bactericidal and not bacteriostatic effect.
22This is important because the bacteria could begin to grow after reduction of the bacteriostatic effect of sealers. Furthermore, DCT method is an appropriate method for the evaluation of antibacterial effect of solid surfaces since it is almost independent of sealer solubility or penetration. We used E. faecalis as a test bacterium because it has been shown to be associated with resistant endodontic infections.
23,
24This bacterium has been routinely used inin vitro studies.
25,
26In this study, all the groups in the fresh conditions showed no bacterial growth in both 10 min and 1 h time periods. Furthermore, both MTA-Fillapex and MTA-PG groups in the set conditions showed no bacterial growth in the tested time periods. However, set AH26 sealer group showed positive results in both the time periods and significant increase of bacterial amount was seen in 1 h. Antibacterial property of sealers differs against various bacteria. Mohammadi et al.
27and Shantiaee et al.
28concluded that the antibacterial effect of AH26 on Staphylococcus aureus and Streptococcus mutans was significantly more than Apexit sealer. Morgental et al.
17reported that fresh MTA-Fillapex sealer showed significant antibacterial effect, but in a 7-day set condition, this property was insignificant. However, in the present study, MTA-Fillapex showed significant antibacterial effect in the fresh and set conditions. The set samples in the present study were 3-day set, which can explain the difference in results. The antibacterial effect of MTA-Fillapex decreased over time.
29Furthermore, studies have also evaluated the antibacterial characteristic of MTA-Fillapex and AH26 on E. faecalis biofilms. Faria-Júnior et al.
16reported effective antibacterial property of set samples of MTA-Fillapex sealer against E. faecalis biofilms which was in coordination with this study. According to the results of this study, the film thickness of all sealers was >50 μm (the maximum amount recommended by the ISO).
18The film thickness of AH26 was significantly more than other sealers. However, MTA-PG showed the lowest film thickness (51 μm). Studies have evaluated the film thickness of MTA-based sealers and reported the range of 24 μm.
18Furthermore, Razmi et al. reported the film thickness of AH26 sealer in the acceptable ISO range (24 μm).
30In this study, the film thickness measurements were performed according to the ISO 6876/2001 recommendations. The higher amounts of film thickness in this study in comparison with the similar studies could be attributed to the different accuracies of digital caliper used in the studies.
The present study showed promising results about the antibacterial property of MTA-PG mixture as a root canal sealer. However, further studies including animal studies and also with other bacterial species of oral flora are recommended.
Conclusion
MTA-Fillapex and MTA-PG showed distinct antibacterial effects. AH26 sealer demonstrated more antibacterial effect in the fresh state in comparison with the set state. The film thickness of MTA-PG and MTA-Fillapex was significantly less than AH26.
Acknowledgment
The authors would like to thank the Research Vice Chancellor and Dental and Periodontal Research Center of Tabriz University of Medical Sciences.
Financial support and sponsorship
Nil
Conflicts of interest
The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or non-financial in this article.
MozayeniMAMilaniASMarvastiLAAsgarySCytotoxicity of calcium enriched mixture cement compared with mineral trioxide aggregate and intermediate restorative material705CamilleriJHydration mechanisms of mineral trioxide aggregate46270TorabinejadMParirokhMMineral trioxide aggregate: A comprehensive literature review – Part II: Leakage and biocompatibility investigations190202ParirokhMTorabinejadMMineral trioxide aggregate: A comprehensive literature review – Part I: Chemical, physical, and antibacterial properties1627ParirokhMTorabinejadMMineral trioxide aggregate: A comprehensive literature review – Part III: Clinical applications, drawbacks, and mechanism of action40013BerBSHattonJFStewartGPChemical modification of proroot mta to improve handling characteristics and decrease setting time12314HollandRMazuqueliLde SouzaVMurataSSDezan JúniorESuzukiPInfluence of the type of vehicle and limit of obturation on apical and periapical tissue response in dogs' teeth after root canal filling with mineral trioxide aggregate6937Salem MilaniABanifatemehARahimiSJafarabadiMAThe effect of using propylene glycol as a vehicle on the microhardness of mineral trioxide aggregate436DuarteMAAlves de AguiarKZeferinoMAVivanRROrdinola-ZapataRTanomaru-FilhoMEvaluation of the propylene glycol association on some physical and chemical properties of mineral trioxide aggregate56570Salem MilaniAFroughreyhaniMCharchi AghdamSPournaghiazarFAsghari JafarabadiMMixing with propylene glycol enhances the bond strength of mineral trioxide aggregate to dentin14525Forough ReyhaniMGhasemiNRahimiSMilaniASOmraniEEffect of different endodontic sealers on the push-out bond strength of fiber posts11923Forough ReyhaniMGhasemiNRahimiSSalem MilaniAMokhtariHShakouieSPush-out bond strength of dorifill, epiphany and MTA-fillapex sealers to root canal dentin with and without smear layer24650ZhouHMDuTFShenYWangZJZhengYFHaapasaloMIn vitro cytotoxicity of calcium silicate-containing endodontic sealers5661RazavianHBarekatainBShadmehrEKhatamiMBagheriFHeidariFBacterial leakage in root canals filled with resin-based and mineral trioxide aggregate-based sealers599603BósioCCFelippeGSBortoluzziEAFelippeMCFelippeWTRiveroERSubcutaneous connective tissue reactions to iRoot SP, mineral trioxide aggregate (MTA) fillapex, diaRoot bioAggregate and MTA66774Faria-JúniorNBTanomaru-FilhoMBerbertFLGuerreiro-TanomaruJMAntibiofilm activity, pH and solubility of endodontic sealers75562MorgentalRDVier-PelisserFVOliveiraSDAntunesFCCogoDMKopperPMAntibacterial activity of two MTA-based root canal sealers112833ZhouHMShenYZhengWLiLZhengYFHaapasaloMPhysical properties of 5 root canal sealers12816BaerJMakiJSIn vitro evaluation of the antimicrobial effect of three endodontic sealers mixed with amoxicillin11703EldenizAUHadimliHHAtaogluHOrstavikDAntibacterial effect of selected root-end filling materials3459ShakouieSSalem MilaniAEskandarnejadMRahimiSFroughreyhaniMGaledarSAntimicrobial activity of tetraacetylethylenediamine-sodium perborate versus sodium hypochlorite against Enterococcus faecalis437ZhangHShenYRuseNDHaapasaloMAntibacterial activity of endodontic sealers by modified direct contact test against Enterococcus faecalis10515Salem-MilaniABalaei-GajanERahimiSMoosaviZAbdollahiAZakeri-MilaniPAntibacterial effect of diclofenac sodium on Enterococcus faecalis1622ZandVMilaniASAminiMBarhaghiMHLotfiMRikhtegaranSAntimicrobial efficacy of photodynamic therapy and sodium hypochlorite on monoculture biofilms of Enterococcus faecalis at different stages of development24551MilaniASJafarabadiMAPakdelMVUsing mineral trioxide aggregate powder as an apical barrier: A bacterial leakage study559ZandVSalem-MilaniAShahiSAkhiMTVazifekhahSEfficacy of different concentrations of sodium hypochlorite and chlorhexidine in disinfection of contaminated resilon conese3525MohammadiZGiardinoLPalazziFShalaviSAntibacterial activity of a new mineral trioxide aggregate-based root canal sealer703ShantiaeeYDianatOJananiAKolahi AhariGIn vitro evaluation of the antibacterial activity of three root canal sealers15Guerreiro-TanomaruJMde Faria-JúniorNBDuarteMAOrdinola-ZapataRGraeffMSTanomaru-FilhoMComparative analysis of Enterococcus faecalis biofilm formation on different substrates34650RazmiHParviziSKhorshidianAComparison of AH26 physicochemical properties with two AH26/Antibiotic combinations610