This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Background:
Coronal restoration of endodontically treated teeth (ETT) with mesio-occluso-distal (MOD) cavities is of a great importance in long-term success of the treatment. This study evaluated the effect of fiber reinforcement on the fracture resistance (FR) of ETT restored with flowable or paste bulk (PB)-fill composite resin compared to conventional composite (CC) resin.
Materials and Methods:
In this in vitro experimental study, eighty maxillary premolars were divided into eight groups (n = 10). The first group was left intact (G
1) and the other groups received MOD cavities along with endodontic treatment. G
2: Remained unrestored while the other experimental groups were restored with three types of composite resin with or without fiber insertion. G
3: CC resin, G
4: PB fill, G
5: Flowable bulk fill (FB). G
6: Fiber + CC, G
7: Fiber + PB, and G
8: Fiber + FB. FR was tested at crosshead speed of 1 mm/min and recorded in Newton. Data were analyzed using one-way analysis of variance and Tukey's tests at significance level of P < 0.05.
Results:
G
1and G2 revealed the highest and the lowest FR, respectively. The mean FR of the testing groups in Newton was as follows: G
1= 1204.8
A, G
2= 352.1
C, G
3= 579.6
BD, G
4= 596.7
BD, G
5= 624.9
BDE, G
6= 858.3
E, G
7= 529.6
CB, and G
8= 802.5
DE. Different uppercase letters indicate the significant difference between the groups.
Conclusion:
The effect of fiber insertion on FR depended on the type of composite resin; the highest reinforcing effect was obtained in the CC resin + fiber, followed by bulk-fill flowable + fiber, and flowable bulk (FB)-fill composite resin. The strength of the former was significantly higher than the conventional and PB fill with and without fiber.
Coronal restorations of pulpless teeth after endodontic therapy are still a challenging issue.
1The strength of endodontically treated teeth (ETT) could be enormously reduced due to the weak tooth structure resulting from caries, trauma, or previous restorations and loss of pulp chamber roof. The design of restoration and type of restorative materials are very determining in this situation; they not only restore and seal the weakened tooth but also reinforce it.
2Today, resin composites have become the preferred choice of many dentists and patients for the coronal restorations because of their sufficient retention and esthetic and mechanical properties with maximum conservation of tooth structure.
1The latter is a result of their bonding ability to dental substrates that leads to cusp splinting/reinforcing effect.
3It has been debated that intracoronal adhesive composite resin restorations provide internal reinforcement of mesio-occluso-distal (MOD) restorations in ETT without occlusal coverage.
4These restorations may be an alternative restorative treatment if a normal occlusion, without parafunctional habit, is present.
5
Polymerization shrinkage of composite resin, as an inherent property, is considered a major problem so that if the resultant force exceeds the interfacial bond strength, adhesive failure negates the adhesive reinforcement of the weakened cusps.
6With high bond strength, tooth structure may be involved in stress fracture.
7Consequently, incremental technique was suggested to overcome these problems and ensure complete curing to achieve optimum performance of the restoration.
8However, the effectiveness of this sensitive and time-consuming placement on reduction of shrinkage stress was not confirmed by some authors.
9Recently, the “bulk-fill”
materials were introduced into the market. Development in photoinitiator dynamics and increased translucency could allow a deeper light penetration and curing. Therefore, bulk-fill composite resins could be applied in a thickness of 4–5 mm and cured at once with low shrinkage stress. Similar to the conventional composite (CC) resins, this new category is provided in low-viscosity (flowable) and high-viscosity (paste) types.
10
Bulk-fill materials simplify the restorative procedure and save clinical time, especially in wide and deep cavities. Recently, better performance of these composite resins, compared to conventional ones, in extensive MOD cavities has been reported in terms of shrinkage stress and fracture resistance (FR).
11However, this result was not supported in two other situations on FR of ETT, with similar FR for two types of composite resins.
12,
13
The development of different types of fibers, such as polyethylene or glass fiber in fiber-reinforced composite, has increased the resin composite applications. Fibers have the ability to reduce polymerization shrinkage, tolerate tensile stress, and stop crack propagation in resin composite materials.
14Ribbond (Ribbond, Seattle, WA, USA) is a polyethylene fiber with woven network that allows an infusion of the resin into the fibers. The fiber network, higher modulus of elasticity, and lower flexural modulus of the polyethylene fibers are believed to have a modifying impact on the interfacial stresses developed along the adhesive interface and allow efficient force transmission.
13,
15Therefore, they could act as stress relievers in restored teeth and may prevent unfavorable subgingival fracture of composite restorations and increase the reparability of fractured teeth.
16Despite some reports on the beneficial effect of fiber reinforcement in composite resin restorations on FR of ETT,
13,
17no significant strengthening effect has also been reported.
12To the best of our knowledge, there was no study evaluating the effectiveness of using fibers beneath bulk-fill resin composites. Therefore, the present study aimed to analyze fiber reinforcement on the fracture strength (FR) and failure mode of flowable and paste bulk (PB)-fill resin composites in endodontically treated premolars.
Materials and Methods
The materials used in this in vitro experimental study are listed in
Table 1. Eighty freshly extracted human maxillary premolars with approximately the same sizes (measured mesiodistally and buccolingually by a digital caliper) and complete root formation were selected. The teeth were checked to be free of caries, any restorations, fractures, or cracks through transillumination technique. After removing any soft-tissue deposits by hand scaler and being stored in chloramine-T solution at 4°C for 24 h, the teeth were stored in distilled water up to 1 month and randomly assigned to eight groups, ten teeth in each.{Table 1}
Group 1: Intact teeth with no cavity preparation or root canal treatment were used as control samples
Groups 2–8: Standard MOD cavities were prepared with diamond bur (#57 Teezkavan, Tehran, Iran). The occlusal isthmus of the cavities was 1/3 of the intercuspal distance, and the proximal box was 2/3 of the buccopalatal width. The gingival floor was placed 1 mm above the cementoenamel junction (CEJ). The cavosurface margins were prepared at 90°. The preparation dimensions were checked using a periodontal probe in all samples. Then, standard endodontic access cavities were prepared using a high-speed bur (#245, Teezkavan, Tehran, Iran) and water coolant. Thereafter, the canals were instrumented with k-file with a step-back technique up to size 70 and 5.25% sodium hypochlorite irrigation between each file. After instrumentation, the teeth were rinsed with distilled water for final irrigation and obturated with gutta-percha and AH Plus sealer (Dentsply DeTrey, Konstanz, Germany) by cold lateral condensation technique. The chamber was cleaned and excess gutta-percha was removed and sealed with a thin layer of resin-modified glass-ionomer cement (GC, Tokyo, Japan). Then, the teeth were stored in 100% humidity for 7 days before restorative procedure
Group 2: MOD cavities were not restored and were used as positive control
Group 3 (CC): After drying the cavities, the surfaces of the cavity wall were etched with 37% phosphoric acid gel (Denfil, Vericom, Korea) for 15 s and rinsed with water for 15 s. Following blot drying of cavity surfaces, Tetric-N-Bond adhesive (Ivoclar Vivadent, Schaan, Liechtenstein) was actively applied for 20 s, and the solvent was air-dried for 5 s and light-cured for 20 s by a QTH light-curing unit with intensity of 600 mw/cm
2(VIP Junior, Bisco, USA). Conventional nanohybrid resin composite (shade A2, Tetric-N-Ceram [TN]], Ivoclar Vivadent, Schaan, Liechtenstein) was used to restore the whole cavity walls through incremental technique with maximal thickness of 2 mm. Each increment was light cured for 40 s
Group 4 (PB fill, PB): After the process of etch and bond, as were done for teeth in Group 3, the cavities were filled with a bulk-fill composite resin (shade IVA, TN bulk fill, TB, Ivoclar Vivadent, Liechtenstein) in one increment up to 4–5 mm thickness and then were light cured for 40 s
Group 5 (flowable bulk [FB]-fill composite resin, FB): Having done the procedure of etching and bonding, the cavities were filled with a low-viscosity bulk-fill composite resin (X-tra base, Voco GmbH, Hanau, Germany) at up to 4 mm in thickness and cured for 40 s. The remaining parts of the cavities were restored with a nanohybrid composite resin (TN) at maximum 2 mm thickness and then light cured for 40 s
Group 6 (fiber + CC): Polyethylene fiber (Ribbond-THM, Ribbond, Seattle, WA, USA) was cut so that the buccal and lingual walls were covered with 2 mm of the fiber from the cavity floor. Fibers were wetted with Ribbond wetting resin (Ribbond, Seattle, WA, USA) in darkness for 10 min before the restorative procedures. After etching and bonding like previous groups, a thin layer (at least 1 mm) of flowable composite resin (Tetric flow, Ivoclar Vivadent, Schaan, Liechtenstein) was applied to the cavity floor where the fiber was seated. Next, a piece of wetted fiber was pressed through the flowable composite resin in a buccolingual direction to be in close contact in the buccal and lingual walls and cured for 20 s. The remaining cavity was incrementally restored by CC resin (TN) like what was done in Group 3
Group 7 (fiber + PB): Similar to previous groups, the PB-fill composite resin was used to restore the cavities following insertion of fiber
Group 8 (fiber + FB): After insertion of fiber, the cavities were restored with flowable bulk-fill composite resin.
Remaining in distilled water at 37°C for 24 h, all restorations were finished and polished with Sof-Lex disc (3M ESPE, St. Paul, MN, USA), and rubber points. The teeth were subjected to thermocycling (5000 cycles at 5°C and 55°C, with 30-s dwell time and 5-s transfer time). All the specimens were embedded vertically in self-curing acrylic resin (Acropars, Tehran, Iran) in a Teflon mold up to 1 mm apical to the CEJ while the tooth's long axis was perpendicular to the base of the mold.
FR test was performed by a universal testing machine (Instron model 4302, Darmstadt, Germany). The compressive load was delivered using a 6-mm stainless steel sphere at crosshead speed of 1 mm/min, perpendicular to the long axis of the tooth. The sphere touched the buccal and lingual cusps of the teeth until a fracture occurred. The forces needed for fracture were recorded in Newton (N). To determine the failure modes, the fractured specimens were observed under a stereomicroscope at magnification of ×40. Failure modes were classified as:
Restorable failures when the fracture line was above the CEJ or 1 mm or less apical to the CEJ
Nonrestorable failures and vertical fracture when the fracture line was more than 1 mm apical to the CEJ.
18
After verifying normal distribution with the normality test (Kolmogorov–Smirnov test), data were analyzed using one-way analysis of variance and Tukey's honest significance difference multiple comparison tests at the significance level of P < 0.05.
Results
The mean and standard deviation of FR in each of the eight groups are presented in
Table 2and
Figure 1. Power analysis showed that the sample size of this study resulted in acceptable power values (80% ≤ power). Group 1 (intact teeth, 1204 ± 252) demonstrated the highest strength and a significant difference with all groups (P < 0.001). Group 2 (unrestored teeth: 352 ± 143) had the lowest FR showing a significant difference (P < 0.05) with the other groups except G7. In our assessment, there was no statistically significant difference among the FR of G3, G4, and G5 (P > 0.05), indicating similar FR for three types of composite resin without fiber.
Fiber insertion resulted in a significantly higher FR only for CC resin (G6 = 858 ± 215 vs. G3 = 579 ± 114, P = 0.01). G6 had the highest strength with a significant difference with other experimental groups (P < 0. 03) except for G5 (624.9 ± 182) and G8 (802 ± 201). There was no noteworthy difference between G5 and G8. Fiber in combination with PB-fill composite resin revealed no reinforcing effect and showed the lowest FR (G7 = 529 ± 124) among the experimental groups that were significantly lower than that of G6 and G8 (P = 0.003 and P = 0.002, respectively.).{Table 2}
Mean fracture resistance and standard deviation among the groups. G1 (Control, Intact teeth), G2 (Control, unrestored teeth), G3 (conventional composite), G4 (paste bulk-fill), G5 (flowable bulk-fill), G6 (Fiber+ conventional composite) G7 (Fiber + paste bulk-fill), G8 (Fiber + flowable bulk-fill).
Figure 1
Table 3presents the frequency of different failure modes in the experimental groups. Failure mode analysis revealed that the most fracture pattern was nonrestorable in groups with no fiber (G3 and G4), although in G5, the same level of fracture pattern was observed. In fiber reinforcement groups, the main fracture pattern was restorable.
Figure 2and
Figure 3represent restorable and nonrestorable fractures, respectively.{Table 3}
Restorable fracture.
Figure 2
Nonrestorable fracture.
Figure 3
Discussion
The present study evaluated the FR of ETT with MOD cavities and intracoronally (no cuspal coverage) restored with different types of composite resins reinforced by fiber. Although cusp coverage is recommended as the definite restoration in ETT, we used intracoronal restoration to mimic a clinical scenario in which ETT cannot be restored permanently like in case of endodontic or periodontal problems. In the maintenance phase, preservation of restored ETT with no catastrophic fracture is an important issue. It is evidenced that cusp fracture is one of the main reasons for loss of ETT. In this study, we used TB as the bulk-filled material, because of its sculpt-able consistency, and that it can be applied in one increment; also, it was considered suitable for posterior final restoration as described by the manufacturer.
19Furthermore, x-tra base (low-viscosity bulk fill) was used due to its higher filler content (approximately 75 wt%) and flexural strength similar to other employed composite resins.
20
The results of our study revealed that also high-viscosity TB composite resin had a comparable FR compared to conventional counterpart (TN composite). These findings are in agreement with the results of Atalay et al. and Kemaloglu et al. and Yasa et al. studies.
12,
13,
21
These authors reported that CC resin and bulk-fill composite resin showed no difference in the strength of restored teeth. Composition, filler content of resin composites, and their elastic modulus are the important factors attributed to polymerization shrinkage stress and subsequent clinical fractures.
22Benetti et al.'s study showed that Tetric-EvoCeram (TEC) bulk-fill composite resin had the same polymerization contraction stress and gap formation similar to TEC CC resin.
6Do et al. also showed that TEC bulk fill had the lowest cuspal flexure than other tested bulk-fill composite resins.
23According to El-Damanhoury and Platt, TEC bulk fill exhibited lower stress than the control material with good mechanical properties, enabling it as a final restoration.
24Rosatto et al. revealed that the use of bulk-filling technique resulted in significantly lower cuspal strains and shrinkage stresses with higher FR.
11TB used in this study demonstrated a higher depth of cure due to the improvements in their initiator (Ivocerin) and increased translucency.
25,
26It has filler content similar to TN (around 77%–80%). This may contribute to the similar FR obtained for two types of composite resins. Akbarian et al. also indicated that silorane-based composite with less volumetric shrinkage compared with dimethacrylate-based composite, both had a similar FR.
27It seems that polymerization shrinkage stress does not directly affect FR. Such conflicting results might be due to the variety of types and dimensions of the cavities and the direction of the applied load on the examined teeth. Our study showed that the FR of ETT restored with CC resin with Ribbond fiber was significantly higher than that without fiber. Ribbond is a leno-woven ultra-high-molecular-weight polyethylene ribbon. It has a high tensile strength, modulus of elasticity and fracture toughness, and biocompatible and excellent optical properties.
28This is consistent with Ayad et al.'s results, indicating that polyethylene fiber has a modifying effect on the developing interfacial stresses and has a strengthening effect on the remaining tooth structure.
29
Khan et al. demonstrated that both polyethylene ribbon and glass fiber significantly enhanced the FR of MOD composite resin restorations with no difference between the two groups. It was thought that the fiber network would absorb and change the stress at the restorative/adhesive interface and reduce the risk of fracture.
30Furthermore, fibers would replace a part of the composite resin increment and decrease in the overall volumetric polymerization shrinkage of the composite resin. Hshad et al. also reported the considerably beneficial effect of polyethylene ribbon fiber on the fracture strength of ETT restored with CC resin.
31In contrast to our results, Göktürk et al. found no significant difference between the fracture strength of the restored premolars using CC resin with and without fiber insertion.
32Such contradictory results could be attributed to the variation in the composite resin brands, types of the teeth (premolars vs. molars), cavity size, loading device, and the experimental situation.
In contrast to the effect of fiber reinforcement with CC resin in our study, this effect was not observed using PB-fill composite resin and fiber + PB-fill composite resin showed the lowest mean FR among the experimental groups. It was not statistically different from CC resin and bulk composite resin groups. This phenomenon might be explained due to the presence of a weak interaction and gap formation between the PB-fill composite resin and the fiber. The possibility of this effect might be less in case of using flowable composite resin; hence, establishment of a unique united structure and chemical bond between flowable composite resin, fiber, and restorative resin is essential in obtaining a positive effect of fiber in the FR,
13which is easily achieved in CC resin placed in increments of maximum 2 mm while this integrity may be not achieved with 4 mm bulk layer. The possible presence of void between the bulk layer of the composite resin and the fiber might create some flexure of the restoration and subsequent flaw formation and the reduced FR of the teeth. When bulk-fill flowable composite resin was used with fiber, a significantly higher strength was obtained although this difference was not statistically significant. Considering similar fracture strength for bulk-fill flowable and CC resins with fiber reinforcing, the former approach could be suggested to simplify the composite resin placement in ETT with extensive MOD cavities. This provides improved adaptation and shortened restorative time. In the literature, only in a recent study by Takce et al., the fiber was used beneath a bulk-fill flowable composite resin (smart dentin replacement). These authors concluded that this approach behaves similar to CC resin with fiber in terms of FR in ETT. However, bulk-fill flowable without fiber and PB fill with or without fiber were not compared in their study. In the present study, the majority of the restorable failure pattern was observed in groups with fiber reinforcement which was similar to the intact tooth.
33Recently, Eliguzeloglu Dalkılıç et al. evaluated the effect of two fiber insertion techniques on the fracture strength of restored teeth using FB-fill composite resin.
34They found no increase in the fracture strength values; however, fiber increased the favorable fracture modes consistently with our findings.
34These results are attributed to the stress distributive effect of polyethylene fiber, as shown in Yanyu et al. and Hshad et al.'s studies.
31,
35However, the specimens restored with conventional nanohybrid and bulk-fill composite resins were more prone to unrestorable fractures.
This in vitro study was conducted under a static load with no simulation of in vivo situation. Considering the intraoral conditions, further in vivo studies should be performed to evaluate the effect of different fibers with different bulk-fill composite resins in restoring the ETT.
Conclusion
Based on the limitations of this study, the following results were reached:
The conventional nanohybrid composite resin and flowable and PB-fill composite resins without fiber had comparable FRs
Fiber significantly increased the fracture strength of endodontically treated premolars restored with CC resin. Although this reinforcing effect was not statistically significant for flowable and PB-fill composite resins, the strength of FB-fill composite resin with fiber reached the level of CC resin with fiber. Therefore, it is suggested that FB-fill composite resin with fiber simplifies the composite placement with advantage of better adaptability
The fiber reinforcement with conventional and FB-fill composite resin could be suggested as intermediary restoration in ETT with questionable prognosis until subsequent definitive restorations.
Acknowledgement
The authors thank the vice-chancellery for research, Shiraz University of Medical Sciences, Shiraz, Iran, for supporting this research (Grant #12597).This article is based on the thesis by N.Ghaderi. The authors all thank Dr. Vosough of the Dental Research Development Center of the school of Dentistry for the statistical analysis and Dr. Shokrpour for his editorial assistance.
Financial support and sponsorship
This work was supported by Shiraz University of Medical Sciences, Shiraz, Iran (grant no. 12597).
Conflicts of interest
The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or non-financial in this article.
FokkingaWALe BellAMKreulenCMLassilaLVVallittuPKCreugersNHEx vivo fracture resistance of direct resin composite complete crowns with and without posts on maxillary premolars2307EdelhoffDSorensenJATooth structure removal associated with various preparation designs for posterior teeth2419HürmüzlüFKiremitçiASerperAAltundaşarESisoSHFracture resistance of endodontically treated premolars restored with ormocer and packable composite83840SoaresPVSantos-FilhoPCMartinsLRSoaresCJInfluence of restorative technique on the biomechanical behavior of endodontically treated maxillary premolars.Part I: Fracture resistance and fracture mode307KrejciIDucODietschiDde CamposEMarginal adaptation, retention and fracture resistance of adhesive composite restorations on devital teeth with and without posts12735BenettiARHavndrup-PedersenCHonoréDPedersenMKPallesenUBulk-fill resin composites: Polymerization contraction, depth of cure, and gap formation190200HaakRWichtMJNoackMJMarginal and internal adaptation of extended Class I restorations lined with flowable composites2319LazarchikDAHammondBDSikesCLLooneySWRueggebergFAHardness comparison of bulk-filled/transtooth and incremental-filled/occlusally irradiated composite resins12940AbbasGFlemingGJHarringtonEShortallACBurkeFJCuspal movement and microleakage in premolar teeth restored with a packable composite cured in bulk or in increments43744KrämerNLohbauerUGarcía-GodoyFFrankenbergerRLight curing of resin-based composites in the LED era13542RosattoCMBicalhoAAVeríssimoCBragançaGFRodriguesMPTantbirojnDMechanical properties, shrinkage stress, cuspal strain and fracture resistance of molars restored with bulk-fill composites and incremental filling technique151928AtalayCYaziciARHoruztepeANagasEErtanAOzgunaltayGFracture resistance of endodontically treated teeth restored with bulk fill, bulk fill flowable, fiber-reinforced, and conventional resin compositeE131E140KemalogluHEmin KavalMTurkunMMicoogullari KurtSEffect of novel restoration techniques on the fracture resistance of teeth treated endodontically: An in vitro study61822LassilaLVNohrströmTVallittuPKThe influence of short-term water storage on the flexural properties of unidirectional glass fiber-reinforced composites22219ShafieiFTavangarMSGhahramaniYFattahZFracture resistance of endodontically treated maxillary premolars restored by silorane-based composite with or without fiber or nano-ionomer2006OskoeePAAjamiAANavimipourEJOskoeeSSSadjadiJThe effect of three composite fiber insertion techniques on fracture resistance of root-filled teeth4136KhanSIAnupamaRDeepalakshmiMKumarKSEffect of two different types of fibers on the fracture resistance of endodontically treated molars restored with composite resin16771ShafieiFDoozandehMGhaffaripourDEffect of Different Liners on Fracture Resistance of Premolars Restored with Conventional and Short Fiber-Reinforced Composite Resins28:e3049KimEHJungKHSonSAHurBKwonYHParkJKEffect of resin thickness on the microhardness and optical properties of bulk-fill resin composites12835LeprinceJGPalinWMVanackerJSabbaghJDevauxJLeloupGPhysico-mechanical characteristics of commercially available bulk-fill composites9931000YasaBArslanHYasaEAkcayMHatirliHEffect of novel restorative materials and retention slots on fracture resistance of endodontically-treated teeth96102YeolekarTSChowdharyNRMukundaKSKiranNKEvaluation of microleakage and marginal ridge fracture resistance of primary molars restored with three restorative materials: A comparative in vitro study10813DoTChurchBVeríssimoCHackmyerSPTantbirojnDSimonJFCuspal flexure, depth-of-cure, and bond integrity of bulk-fill composites46873El-DamanhouryHPlattJPolymerization shrinkage stress kinetics and related properties of bulk-fill resin composites37482LassilaLVNagasEVallittuPKGaroushiSTranslucency of flowable bulk-filling composites of various thicknesses315FlurySHayozSPeutzfeldtAHüslerJLussiAJDepth of cure of resin composites: Is the ISO 4049 method suitable for bulk fill materials?5218AkbarianGAmeriHChasteenJEGhavamnasiriMFracture resistance of premolar teeth restored with silorane-based or dimethacrylate-based composite resins2007RudoDNKarbhariVMPhysical behaviors of fiber reinforcement as applied to tooth stabilization735AyadMFMaghrabiAAGarcía-GodoyFResin composite polyethylene fiber reinforcement: Effect on fracture resistance of weakened marginal ridges1336AkmanSAkmanMEskitasciogluGBelliSInfluence of several fibre-reinforced composite restoration techniques on cusp movement and fracture strength of molar teeth40715HshadMEDalkılıçEEOzturkGCDogruerIKorayFInfluence of different restoration techniques on fracture resistance of root-filled teeth: In vitro investigation1629GöktürkHKaraarslanEŞTekinEHologluBSarıkayaIThe effect of the different restorations on fracture resistance of root-filled premolars196TekçeNPalaKTuncerSDemirciMSerimMEInfluence of polymerisation method and type of fibre on fracture strength of endodontically treated teeth11522Eliguzeloglu DalkılıçEKazakMHisarbeyliDFildisiMADonmezNDeniz ArısuHCan fiber application affect the fracture strength of endodontically treated teeth restored with a low viscosity bulk-fill composite?3126931MiaoYLiuTLeeWFeiXJiangGJiangYFracture resistance of palatal cusps defective premolars restored with polyethylene fiber and composite resin498502