This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Background:
The aim of this study was to compare dentinal crack formation in root canal walls following 3 single file systems with continuous rotation under a scanning electron microscope (SEM).
Materials and Methods:
In this SEM study, seventy mandibular premolars were randomly divided into 5 groups. 3 experimental groups (n = 20) and 2 control groups (n = 5) as follows: Group I: Neolix NiTi file system, Group II: OneShape systems, Group III: OneCurve file system, positive control: conventional Hand File system, negative control: unprepared. After root canal preparations, the roots were sectioned at 3, 6, and 9 mm from the apex with water irrigation. The sections were inspected in all directions under SEM at × 100 magnification to determine the presence of cracks. The Chi-square test was used to analyze the data. There is a statistically significant difference in the crack formation between the apical third (P = 0.012) and coronal third (P = 0.002) when comparing all the 5 groups. No significant difference is found in the middle third (P = 0.46). P < 0.05 is considered statistically significant.
Results:
Maximum cracks in the apical third were seen with One Shape file 11 (55%) and in the coronal third with Neolix NiTi 14 (70%). There is a statistically significant difference in the crack formation only in OneCurve when comparing the apical, middle, and coronal third for the individual group (P = 0.042).
Conclusion:
There was a significant difference in crack formation in apical and coronal third. OneCurve caused the least incidence of cracks when compared to other file systems. OneCurve file system can be a choice for canal preparation over Neolix Niti and OneShape.
Root canal treatment aims to eradicate tissue debris as well as microorganisms from the root canal system. Chemomechanical preparation (CMP) achieved through instrumentation provides a canal with a larger diameter, smoother walls, and optimal apical size to allow copious irrigation along with 3-dimensional obturation. CMP is critical for successful endodontic treatment outcome.
1The evolution of file systems over the years from stainless steel hand files system to NiTi rotary file system has made CMP effortless and predictable. Normally while preparing the root canal, the multiple NiTi files of different diameters and taper are used to gradually enlarge the root canal. In the preparation of the root canal, the advent of the single file system (SFS) is an exciting all-new concept. In SFS, only one file is required to prepare the canal to an adequate size and taper, even in narrow and curved canals. In addition to shaping the canal, SFS reduces the working time, lowers cross-contamination, and reduces the instrument fatigue without compromising the cutting efficiency when compared to multiple file systems. SFS is developed for shaping the vast majority of canals, regardless of their length, diameter, or curvature.
2,
3Neolix Neoniti (NEOLIX, Chatres-la-Foret, France), OneShape files (Micro-Mega, Besanc¸on Cedex, France), OneCurve (Micro-Mega Company) are some of the recently introduced SFSs with continuous rotation used for CMP.
2
CMP of root canal induces stresses on dentin and causes microcracks and craze lines into the root dentin. Propagation of microcracks and craze lines over a period of time may lead to vertical root fracture (VRF) which generates serious endodontic complication rendering the tooth for extraction.
4,
5Introduction of scanning electron microscope (SEM) has proved to be a valuable method for the assessment of the ability of endodontic procedures to remove debris from root canals, thus enabling comparison of instruments and instrumentation techniques. SEM images have been used to evaluate the effects of preparation methods on root canal surface, cleaning efficacy of various root canal instruments, and formation of dentinal defects in endodontic practice.
6Khoshbin et al. found that Neolix caused significantly least number of cracks when compared with Mtwo and ProTaper file system.
4According to Das et al., the incidence of crack observed in root dentin was greater after instrumentation with OneShape as compared to HEDM and ProTaper Next.
To the best of the author's knowledge, the literature lacks data on the effect of above mentioned three SFSs on dentin. Hence this study was conceptualized to compare dentinal crack formation in root canal walls following instrumentation with Neolix NiTi, One Shape, and OneCurve SFSswith continuous rotation, to the conventional Hand File system under SEM.
Materials and Methods
This SEM study was performed after Institutional Ethical Committee (IEC) clearance (CDCRI/DEAN/ETHICS COMMITTEE/ENDO/PG-01/19). Freshly extracted, single-rooted, and single canalled 80 mandibular first premolars were collected. Teeth with apical foramen no larger than size #15 K-file with a maximum root curvature of 25°C were included in the study. Teeth with internal or external root resorption, external surface cracks (observed under ×25), root caries, open apex, or canal calcification were excluded (n = 10). The teeth were cleaned with an ultrasonic scaler and then disinfected using 2.5% sodium hypochlorite. They were stored in distilled water to prevent dehydration throughout the study. The crowns of all teeth were decoronated such that the remaining standardized root length is 17 mm that enabled straight-line access to the canal
Figure 1. A silicon impression material was used for coating the external root surface so as to simulate periodontal ligament space. Care was taken to instrument the root canals immediately after setting of polyvinyl siloxane so as to avoid loss of properties of the impression material which is simulating the periodontal ligament
Figure 2a. All roots were subsequently embedded in acrylic blocks
Figure 2b. All samples were randomly divided into 3 experimental groups (n = 20 for each group) and 2 control groups (n = 5 for each group) as follows:
Crowns of all teeth were de-coronated so as to maintain the standardized root length as 17 mm.
Figure 1
A silicon impression material was used for coating external root surface (a) and were subsequently embedded in acrylic blocks (b).
Figure 2
Group I: Neolix NiTi file system (n = 20)
Group II: OneShape systems (n = 20)
Group III: OneCurve file system (n = 20)
Positive control: Conventional Hand File System (n = 5)
Negative control: Unprepared (n = 5).
The working length (WL) was established by inserting a size 10 K file to the root canal terminus and subtracting 1 mm from this measurement. Glide path was prepared using size 10 Kfile up to the WL. Moreover, after each instrument, a size 10 Kfile was used to maintain the canal patency between all steps.
Group I: Root canal preparation with Neolix NiTi file system (n = 20)
Neolix files (Neolix Xavier, Châtres-la-Forêt, France) system has A1 and C1 files. Both files were used with a speed of 300–500 rpm and torque limit of 1.5 N/cm.
5C1 (25/0.12 and 15 mm length) file was used for flaring of the root canal orifice
Figure 3a. A1 (25/0.08) file was then passively used to prepare the middle and apical thirds of the canal. After each use, the file is removed from the canal, and debris is cleaned from the flutes using gauze. The root canals were rinsed with 5 mL 5.25% sodium hypochlorite solution. After reaching the WL a final rinse of the canal was performed.
Root canal preparation done with Neolix NiTi (a), OneShape (b) OneCurve, (c) and conventional Hand File (d) system.
Figure 3
Group II: Root canal preparation with OneShape systems (n = 20)
One-Shape (Micro-Mega, Besanc¸on Cedex, France) system consist of one instrument with a tip size of 25 and a constant taper of 0.06 File operates at Speed-350–450 RPM and Torque-2.5 N/cm
2. Canal preparation is accomplished with a slow in-and-out pecking motion. This movement is repeated till the WL
Figure 3b. After each use, the file is removed from the canal, and debris is cleaned from the flutes using gauze. The root canals were rinsed with 5 mL 5.25% sodium hypochlorite solution. After reaching the WL a final rinse of the canal was performed.
Group III: Root canal preparation with OneCurve file system (n = 20)
OneCurve (Micro-Mega Company) system consists of a file with a tip size of #25 and a constant taper of 0.06 operating at a speed of 300 rpm and 2.5 N/cm
2torque. Canal preparation is accomplished with slow in-and-out pecking till the file reaches the WL
Figure 3c. After each use, the file is removed from the canal, and debris is cleaned from the flutes using gauze. The root canals will be rinsed with 5 mL 5.25% sodium hypochlorite solution. After reaching the WL a final rinse of the canal was performed.
Group IV: Root canal preparation with conventional Hand File system (n = 20)
Roots in the control group were instrumented with stainless steel hand K-files (Mani, Japan). #15 K-file was used as an initial file. Roots were prepared to apical size #25 and prepared up to size # 50 using a step-back technique with 1-mm increments
Figure 3d. Root canal irrigation was completed with 5 mL 5.25% sodium hypochlorite after each file and a final rinse was performed.
After CMP, all the samples were sectioned horizontally at 3, 6, and 9 mm from the apex with the aid of a low-speed handpiece under water coolant using a diamond disc (thickness: 0.3 mm)
Figure 4. Digital image of each section was captured at ×100 magnification using SEM roots with a crack in at least 1 section of the root were classified as cracked
Figure 5and
Figure 6. This included both complete and incomplete cracks originating from the root canal wall and extending to the root surface.
All samples were sectioned horizontally at 3, 6, and 9 mm from the apex with the aid of a low-speed handpiece using a diamond disc.
Figure 4
Digital image of each section at × 100 magnification using SEM (a) Neolix NiTi file system; (b) OneShape file system; (c) OneCurve file system. 1 - at apical third (3 mm); 2 – middle third (6 mm); 3 - coronal third (9 mm), respectively.
Figure 5
Digital image of each section at × 100 magnification using SEM (a) Hand File system; (b) unprepared. 1 - at apical third (3 mm); 2 - middle third (6 mm); 3 - coronal third (9 mm) respectively.
Figure 6
Data were analyzed using SPSS Version 21 (SPSS Inc., Armonk, NY, USA). Results were reported as the frequency of cracks in the 3 sections for each group. The Chi-square test was used to compare the frequency of cracks among the 5 groups, with P < 0.05 considered statistically significant.
Results
Evaluation of crack formation at various levels revealed that apical third (P = 0.012) and coronal third (P = 0.002) showed significant incidence of crack formation compared to middle third (P = 0.46) in all 5 groups
Table 1. In Group I, 14 (70%) samples had a crack in the coronal third; however, there was no statistically significant difference in the incidence of crack at all 3 levels (P = 0.12). In One Shape file group, maximum cracks were seen in apical third (11 [55%]) but it was nonsignificantly different from other levels [Graph 1]. Moreover, in Group III, there was a statistically significant difference in crack formation with the highest incidence at the middle third (P = 0.042).{Table 1}[INLINE:1]
Discussion
Root canal preparation using endodontic files is frequently associated with the formation of some dentinal defects.
7Most of the NiTi instruments with different designs result in incomplete cracks, craze lines, or even VRF, and such defects should be prevented as it necessitates tooth extraction.
5,
8A significant association exists between the amount of dentin removed and crack formation, and excessive widening of the canal increases the risk of VRF.
7Even in the absence of VRF, the presence of cracks can compromise the outcome of endodontic treatment.
1The current study assesses the frequency of microcrack formation using 3 different SFS with continuous rotation and conventional Hand File system with the help of SEM. SFS with continuous rotation was used because of their economic viability, unique design, and presterilized usage with zero cross-contamination.
9
Mandibular premolars were selected for the study because of the high prevalence of VRF as reported by Tamse et al.
10Acrylic blocks and a silicone impression material were used to simulate bone and periodontal ligament respectively. Periodontal ligament simulation acts as a major stress absorber and sways the outcome of such studies.
11In this study, the apical master file was standardized using a file with a tip diameter equivalent to size 25. After canal preparation, all file systems showed dentin crack formation which was in accordance with previous studies.
11,
12In this study, OneShape file showed maximum number of dentinal cracks in the apical third (11 [55%]) and minimum in the middle third (4 [20%]). Das et al. reported similar results in their study.
13It has a triangle cutting edge in the apical part, 2 cutting edges in the coronal part, and a cross-section that progressively changes from 3 to 2 cutting edges between the apical and coronal parts.
13This design may affect shaping forces on root dentin these forces may cause root fracture.
14This could be the probable reason for more cracks in the apical region. No statistically significant difference (P = 0.070) was seen between crack formation at apical, middle, and coronal third for OneShape. Neolix NiTi showed maximum cracks in the coronal third when compared to other file systems which was in accordance with Harandi et al.
5The file is generated using a wire-cut electrical discharge machining process and has rectangular non-similar cross-sections all along its length this file has larger taper (0.08) and increased rotational speed (500 rpm) when compared to the other two file system which generate more stress thus causing dentin damage as suggested by Bier et al.
8This result was contradictory to the results of Harandi et al. and Elham et al.
4,
5No statistically significant difference (P = 0.12) was seen between crack formation at apical, middle, and coronal third for Neolix NiTi.
OneCurve showed maximum cracks in the middle third and minimum in the apical third. OneCurve files are composed of a NiTi alloy that undergoes a patent protected heat treatment (C. Wire), which provided a shape-memory effect. It has the same tip size (size 25) and the constant taper (0.06) of their predecessors but has a different shape design. The variable cross-sections with a triangular-shaped at the tip of the instrument and S-shaped near the shaft are claimed to allow effective cutting and centered trajectory.
15The fie design could be the reason for more cracks in the middle third. It was seen that the experimental groups showed more crack formation than positive control which was in accordance with previous studies that stated rotary instruments cause more dentin damage.
16,
17Significant difference was seen (P = 0.042) between crack formation at apical, middle, and coronal third for OneCurve. A significant difference was seen in the apical third (P = 0.012) and coronal third (P = 0.002) when comparing all file systems.
It should be noted that this study had an in vitro design, though periodontal ligament was simulated using polyvinyl siloxane impression material, it doesn't provide the exact intraoral environment. As the extracted tooth becomes brittle, the incidence of a crack in such teeth increases. Thus, the generalization of results to the clinical setting must be done with caution. Future clinical studies are required to obtain more reliable results.
Conclusion
Within the limitation of this study, it can be concluded that all file systems produce some amount of crack. There was a significant difference in crack formation in apical and coronal third. OneCurve showed a minimal incidence of crack when compared to Neolix Niti and OneShape. Neolix NiTi showed the maximum number of cracks. OneCurve file system can be a choice for canal preparation over Neolix Niti and OneShape in such oval canals.
Financial support and sponsorship
Nil.
Conflicts of interest
The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or nonfinancial in this article.
ShantiaeeYDianatOMosayebiGNamdariMTordikPEffect of root canal preparation techniques on crack formation in root dentin44752SharmaPGoelMVermaSSachdevaGSSharmaNKumarVEntering a new era in endodontics with revolutionary single file systems: A comprehensive review110022ParimooDGuptaRTomerARohillaSSingle file endodontics: boon or myth1025KhoshbinEDonyaviZAbbasi AtibehERoshanaeiGAmaniFThe effect of canal preparation with four different rotary systems on formation of dentinal cracks: An in vitro evaluation1638HarandiAMirzaeeradSMehrabaniMMahmoudiEBijaniAIncidence of dentinal crack after root canal preparation by ProTaper universal, Neolix and SafeSider systems4328ÇiçekEKoçakMMSağlamBCKoçakSEvaluation of microcrack formation in root canals after instrumentation with different NiTi rotary file systems: A scanning electron microscopy study4953ShemeshHBierCAWuMKTanomaru-FilhoMWesselinkPRThe effects of canal preparation and filling on the incidence of dentinal defects20813BierCAShemeshHTanomaru-FilhoMWesselinkPRWuMKThe ability of different nickeltitanium rotary instruments to induce dentinal damage during canal preparation2368ZingePRPatilJComparative evaluation of effect of rotary and reciprocating single-file systems on pericervical dentin20174248TamseAFussZLustigJKaplaviJAn evaluation of endodontically treated vertically fractured teeth5068KansalRRajputATalwarSRoongtaRVermaMAssessment of dentinal damage during canal preparation using reciprocating and rotary files14436CaparIDArslanHAkcayMUysalBEffects of ProTaper universal, ProTaper Next, and HyFlex instruments on crack formation in dentin14824DasSPradhanPKLataSSinhaSPComparative evaluation of dentinal crack formation after root canal preparation using ProTaper Next, OneShape, and Hyflex EDM J Conserve Dent153LamPPPalamaraJEMesserHHFracture strength of tooth roots following canal preparation by hand and rotary instrumentation9971001SerafinMDe BiasiMFrancoVAngerameDIn vitro comparison of cyclic fatigue resistance of two rotary single-file endodontic systems: OneCurve versus OneShape196201GargESarfiSBaliDGargAKComparative evaluation of dentinal defects induced by hand files, hyflex, protaper next and one shape during canal preparation: A stereomicroscopic study16VoraECBhatiaRTamgadgeSEffect of three different rotary instrumentation systems on crack formation in root dentin2018103