This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Considering the studies on the effects of bleaching materials on properties of dental materials, The aims of this in vitro study were to evaluate the effects of two different concentrations of bleaching agents on flexural strength and microhardness of VITA ENAMIC.
In this experimental in vitro study, 30 rectangular-shaped specimens (2 mm width × 2 mm height × 12 mm length) for flexural strength and 30 specimens (5 mm width × 5 mm length × 2 mm height) for microhardness tests were prepared from VITA ENAMIC blocks 12 × 14 × 18 mm. The specimens were polished using silicon-carbide sandpapers 400, 600, 800, 1200, 2000 under flow of water for 60 s each. The prepared samples for flexural strength and microhardness were divided into 3 subgroups (n = 10): control group (C), samples bleached using Opalescence PF 15% (B15), and samples bleached with Opalescence Xtra Boost 40% (B40). Flexural strength measurement was done using a universal testing machine, and microhardness test was done using Vickers. Data were analyzed using analysis of variance and post hoc tests and P < 0.05 was considered significant.
The mean microhardness values of C, B15, and B40 groups were 255.46 ± 3.02, 249.86 ± 4.18, and 235.53 ± 4.61 kgf/mm 2. Opalescence PF 15% and Opalescence Xtra Boost 40% affected microhardness of ENAMIC significantly (P < 0.05). The mean flexural strength values of C, B15, and B40 groups were 155.26 ± 16.13, 142.14 ± 11.52, and 133.39 ± 16.13 MPa. A significant decrease in flexural strength was found between the C and B40 groups (P = 0.007). However, the difference between flexural strength of the C and B15 groups was not significant (P > 0.05).
Our study showed that both concentrations of bleaching agents can affect microhardness of ENAMIC. Moreover, hydrogen peroxide 40% has a negative effect on the flexural strength of ENAMIC.
Achievement of a healthy, natural, and beautiful smile is one of the most important issues in restorative dentistry.
Effects of bleaching agents on teeth depend on various options such as their concentration, bleaching time, and type of stain.
Dental ceramics are widely used in restorative dentistry due to their mechanical and esthetic properties.
CAD/CAM technology results in materials with higher qualities. Moreover, less amount of time is needed for their creation.
VITA ENAMIC is the first hybrid dental ceramic which has a three-dimensional geometry with two penetration networks. One network is a glass-ceramic material and the other is a polymer (methacrylate) which reinforces the glass-ceramic network.
During bleaching procedure, dental ceramics are exposed to bleaching materials. Therefore, their effect on physical and mechanical properties of ceramics has been considerable.
Every year, various studies are conducted on the effects of bleaching agents on properties of restorative materials. Results of some studies are contradictory.
Evaluation of different effects of bleaching agents on VITA ENAMIC is important due to desirable properties of VITA ENAMIC and increasing use of this dental material in recent years.
The purpose of this in vitro study was to evaluate the effects of 2 different concentrations of bleaching agents on flexural strength and microhardness of VITA ENAMIC.
Preparation of samples
In this experimental in vitro study, 30 rectangular-shaped specimens 2/2/12 mm 10for flexural strength test and 30 specimens 5/2/2 mm for microhardness test were prepared from 6 VITA ENAMIC (VITA Zahnfabrik/Germany) blocks 12/14/18 mm. VITA ENAMIC blocks were sectioned using Delta precision sectioning machine (Nemo/Mashhad, Iran) at low speed. The prepared specimens were polished using silicon-carbide sandpapers 400, 600, 800, 1200, 2000 under flow of water for 60 s each.
Bleaching procedure
The prepared samples for flexural strength and microhardness tests were divided into 3 subgroups.
Subgroup (B15)
These specimens were bleached using Opalescence PF 15% (Ultradent/USA) for 14 days, each day 4 h according to the Manufacturer's instructions. During bleaching procedure, specimens were kept in 37°C humid environment in incubator (LTE scientific LTD/Greenfield, Great Britain). Samples were kept in distilled water between bleaching sessions.
Subgroup (B40)
These specimens were bleached using Opalescence Xtra Boost 40% (Ultradent/USA) in 2 sessions 1 week apart, every session 3 times, each time 20 min. Bleaching gel was applied on samples surface. After 20 min, the samples were washed for 30 s. After drying the samples, a new layer of bleaching gel was applied. This procedure was repeated 3 times in each session. Samples were kept in distilled water between bleaching sessions.
Subgroup (C)
Control group samples were kept in distilled water during the procedure and were not bleached.
Flexural strength test
Flexural strength test for all the prepared samples for this test was done using a universal testing machine (koopa pazhoohesh/sari, Iran). Three point bending test was used for measuring flexural strength of prepared samples.
The sample was placed on two supports with the bleaching surface facing the machine's crosshead. There was 10 mm space between the two supports. Crosshead speed was 1.0 mm/min. Loading continued until the sample fractured. Width and height of the sample at the fracture point were measured using digital caliper (Shinwa sokutei/China).
Flexural strength values were calculated using the following equation:
[INLINE:1]
Where F is the failure load (in N), L is the distance between the supports (in mm)
B and H are the width and height of fractured points (all in mm).
Microhardness test
Microhardness test for all the prepared samples for this test was done using Vickers (koopa pazhoohesh, sari, Iran). 300 g force was applied to the samples. Loading time was 30 s. Microhardness was measured in 3 points. The calculated average microhardness of these 3 points was reported as the sample's microhardness.
Statistical analysis
The mean microhardness and flexural strength were calculated for all groups. Data were analyzed using SPSS statistical software package SPSS 17.0 for Windows (SPSS, Chicago, Illinois, USA). Data were analyzed using analysis of variance and post hoc tests. P < 0.05 was considered significant.
Mean Vickers hardness values of VITA ENAMIC and mean flexural strength values are shown in
The mean (standard deviation) microhardness values of C, B15, and B40 groups were 255.46 ± 3.02, 249.86 ± 4.18, and 235.53 ± 4.61 kgf/mm 2, respectively.
A statistically significant difference in microhardness between control group and VITA ENAMIC bleached with opalescence pf 15% (P = 0.011) and opalescence Xtra Boost 40% (P < 0.001) was found.
Furthermore, the difference between microhardness values of VITA ENAMIC bleached with opalescence pf 15% and opalescence Xtra Boost 40% was significant (P < 0.001).
The mean (standard deviation) flexural strength values of C, B15, and B40 groups were 155.26 ± 16.13, 142.14 ± 11.52, and 133.39 ± 16.13 MPa.
There was a statistically significant difference between the flexural strength values of the control group and VITA ENAMIC bleached with opalescence Xtra Boost 40% (P = 0.007).
However, the difference between the control group and VITA ENAMIC bleached with opalescence pf 15% was not significant (P = 0.135) as between flexural strength of samples bleached with opalescence pf 15% and opalescence Xtra Boost 40% (P = 0.394).
The mean microhardness of VITA ENAMIC (kgf/mm2) different letters (a, b, c) represent statistically significant difference. The mean flexural strength of VITA ENAMIC (MPa) different letters (a, b) represent statistically significant difference.
Maintenance of dental restorations that are exposed to saliva and other substances are affected by mechanical properties of restorative materials such as flexural strength and microhardness.
The results of this study showed a significant decrease in microhardness of VITA ENAMIC after bleaching with opalescence pf 15% and Opalescence Xtra Boost 40%.
VITA ENAMIC has two networks which one of these networks is a polymer (methacryl).
Türker and Biskin declared that 10% and 16% carbamide peroxide decreased microhardness of feldspathic porcelain.
Furthermore, they are some articles with conflicting results. In Bahannan's research, 10%, 20%, and 35% carbamide peroxide did not affect the microhardness of feldspathic porcelain.
In this study, a statistically significant decrease was found in flexural strength of VITA ENAMIC after bleaching with Opalescence Xtra Boost 40%. However, the decrease in flexural strength of specimens bleached with Opalescence PF 15% was not significant. Furthermore, there was no statistically significant difference between flexural strength of specimens bleached with Opalescence Xtra Boost 40% and opalescence pf 15%. Flexural strength is especially notable where intense occlusal stresses are applied such as in long-span fixed dental prosthesis.
It was suggested in a study that 16% carbamide peroxide did not affect the flexural strength of composite resins and it was declared that filler particles, the chemical bondblocks promoted by coupling agents at the interface of resin-filler were some factors that prevented the expansion of cracks in composites during flexural strength test.
In general, the conflicting results may be due to properties of the studied materials.
According to our study, bleaching agents can affect microhardness of VITA ENAMIC. Moreover, hydrogen peroxide 40% affects the flexural strength of VITA ENAMIC. Hence, the clinicians should prevent the bleaching gel from coming into contact with VITA ENAMIC restorations.
The limitation is that saliva and mastication forces are absent in our study. These factors may affect VITA ENAMICs respond to bleaching gels.
The microhardness of VITA ENAMIC decreased after bleaching procedure using Opalescence PF 15% or Opalescence Xtra Boost 40% The effects of bleaching materials on microhardness of VITA ENAMIC was concentration dependent The flexural strength of VITA ENAMIC decreased after bleaching with Opalescence Xtra Boost 40% Opalescence PF 15% did not affect flexural strength of VITA ENAMIC No significant differences were observed between flexural strength of VITA ENAMIC bleached with opalescence pf 15% and opalescence Xtra Boost 40%.
Acknowledgments
The authors would like to thank Dental materials Research Center and Research Council of Babol University of Medical Sciences.
Financial support and sponsorship
Babol university of medical sciences.
Conflicts of interest
The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or nonfinancial in this article.