This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

1735-3327 2008-0255 Wolters Kluwer India Pvt. Ltd. India
DRJ-19-90 10.4103/1735-3327.359327 Original Article A comparative evaluation of fracture toughness, flexural strength, and acid buffer capability of a bulk-fill alkasite with high-strength glass-ionomer cement: An in vitro study Battula Madhuri S Kaushik Mamta Mehra Neha Raj Vishnu Department of Conservative Dentistry and Endodontics, Army College of Dental Sciences, Secunderabad, Telangana, India Department of Conservative Dentistry and Endodontics, Army College of Dental Sciences, Secunderabad, Telangana, India Department of Conservative Dentistry and Endodontics, Army College of Dental Sciences, Secunderabad, Telangana, India Department of Conservative Dentistry and Endodontics, Army College of Dental Sciences, Secunderabad, Telangana, India Address for correspondence:Madhuri Battula, Army College of Dental Sciences, CRPF Road, Jai Jawaharnagar Post, Hyderabad - 500 087, Telangana, India mailsaimadhuri@gmail.com 2022 19 1 90 90 22 11 2021 Copyright: © Dental Research Journal 2022

This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

Background:

Although glass-ionomer cement (GIC) has many unique properties and advantages, it still lacks favorable mechanical properties. Cention N is a recent alkasite material with excellent mechanical properties. The purpose of this study was to compare the mechanical properties (fracture toughness [FT] and flexural strength [FS]) and acid buffer capability of an alkasite material to GIC.

Materials and Methods:

In this in vitro study, a total of 60 samples were prepared using Cention N or GIC. Twenty specimens (n = 10) were prepared using beam-shaped Teflon molds for FS, and twenty specimens (n = 10) were prepared with a similar mold with a notch for FT. These were evaluated on a universal testing machine using a three-point bend test. Twenty (n = 10) disk-shaped specimens were prepared for acid buffer capability. The samples were stored in distilled water for a week. This was followed by immersion in lactic acid with a pH of 4 for calculation of the materials acid buffering capacity at 30 and 60 min from exposure using a pH meter. The data obtained were tabulated and subjected to Kolmogorov–Smirnov test and Shapiro–Wilk test to assess the normal distribution and further analyzed using the Student's t-test to assess the level of significance, P < 0.05 was considered statistically significant.

Results:

The mean FT, FS, and acid buffer capability of Cention N were significantly higher than GIC at P < 0.05.

Conclusion:

The present study surmised that Cention N exhibited higher FT, FS, and acid buffer capability than GIC.

Buffering capacity Cention N flexural strength glass-ionomer cement mechanical property
</sec> <sec> <title>Introduction

Wilson and Kent introduced the first glass-ionomer cement (GIC) in 1972 and called glass polyalkenoate cement. 1 , 2 It has anticaries properties, such as fluoride ion release and recharge abilities, and it prevents enamel decalcification. It also exhibits inhibition of bacterial acid metabolism. Other beneficial properties of GICs include adhesion to the tooth structure, a similar coefficient of thermal expansion as dentin, and biocompatibility. 3 However, the major disadvantages of the GIC are its poor mechanical properties such as poor fracture toughness (FT), low flexural strength (FS), brittleness, and low compressive strength. 3 , 4 Hence, it is not a suitable restorative material in load-bearing areas.

Cention N (Ivoclar Vivadent) is a new alkasite, tooth-colored, and bulk fill direct restorative material that resembles ormocer or compomer and is a subgroup of composite resin. This can be used with or without the application of an adhesive, depending on the retention features of the tooth preparation. It is a self-curing material whose setting can be expedited by light curing. This new material is effective in releasing acid neutralizing ions as it contains alkaline filler. 5 It is a urethane dimethacrylate (UDMA) based dual-curing restorative material. The powder contains various glass fillers, initiators, and pigments, while the liquid comprises dimethacrylates and initiators. It is radiopaque and contains alkaline glass fillers capable of releasing calcium, fluoride, and hydroxide ions. 5 , 6 It displays a high polymer network density and degree of polymerization over the complete depth of the restoration, due to the cross-linking methacrylate monomers in combination with a stable, efficient self-cure initiator. 7

The success rate of restorative treatment depends on physical, biological, and pathophysiological principles and thorough knowledge of mechanical and chemical properties of dental tissues and materials.

An in vitro study concluded that Cention N could be used for Class V cavities, as it would prevent caries at restoration margins by releasing calcium and fluoride ions. 8 Various other studies also showed that Cention N has significantly higher compressive, tensile strength, and shear bond strength when compared with GIC. 4 , 9 , 10 , 11 , 12 , 13 However, there is limited data about FT, FS, and acid buffer capability. 5 , 12 , 14 , 15

Thus, this study aimed to assess FT, FS, and acid buffer capability of Cention N and compare it to GIC (GC Corporation, Tokyo, Japan). The null hypothesis was that there is no difference in the FT, FS, and acid buffer capability of Cention N and GIC.

Materials and Methods

In this in vitro study, test materials and their compositions used are provided in Table 1. The sample size was calculated using G Power software (version 3.1.9.4). Based on the previous studies 12 , 16 and keeping the standard values of alpha error at 0.05 and the power of the study at 80%, the minimum sample size of the study is 30 per group and 10 in each subgroup. Sixty Teflon mold samples were prepared as per the specifications of tests using GIC (N = 30) and Cention N (N = 30).{Table 1}

Flexural strength

Ten beam-shaped Teflon mold samples measuring 25 mm × 2 mm × 2 mm Figure 1a were prepared for each test material. The GIC and Cention N were mixed as per manufacturer instructions. 6 They were inserted into the mold, covered with a polyester strip at the top, and compressed with a glass plate under a constant load of 500 g for 10 min. The samples were then stored at 37°C with a relative humidity of 100% for 50 min. They were removed from the molds and stored for 24 h at 37°C in distilled water before being subjected to a three-point bending test at a crosshead speed of 0.5 mm/min using a universal testing machine (UTM) (AG 15, Shimadzu Co., Kyoto, Japan).

Schematic diagram of specimens showing (a) Flexural strength, (b) Fracture toughness, and (c) Acid Buffer Capability.

Figure 1

Fracture toughness

Teflon mold samples with dimensions 25 mm × 2.5 mm × 5 mm and a single knife-edge notch of 2.5 mm depth and 0.5 mm width Figure 1b were prepared for each test material. The FT was determined by subjecting the prepared specimens to transverse bending according to the method outlined in the American Society for Testing and Materials specification E-399-90 17 with a three-point bending test was carried out at a crosshead speed of 0.5 mm/min using a UTM. FT (K 1C) (MPa m 1/2), was calculated.

Acid buffer capability test

Disk-shaped Teflon mold samples measuring 10 mm × 2 mm Figure 1c were prepared for GIC (n = 10) and Cention N (n = 10). The samples were kept at room temperature for 10 min and then stored in distilled water for a week. At the end of 1 week, the specimens were immersed in a 50 ml plastic tube with 5 ml of a lactic acid solution of pH 4.0. 16 A pH electrode (LI 120, ELICO Ltd) connected to a pH meter was placed at the center of the tube. The change in pH was noted 30 and 60 min after immersion.

Statistical analysis

Kolmogorov–Smirnov test and Shapiro–Wilk test were used to assess the normal distribution of the two groups. An insignificant value in each of the two tests with respect to each of the two groups in all the four parameters (FS, FT, and acid buffer capacity at 30 and 60 min) tells us that data follows normal distribution Table 2. In other words, it tells us that the data are normally distributed in the two groups and so we can now proceed for further evaluation of data using the parametric test of significance.{Table 2}

The data were then analyzed by the t-test using SPSS 20.0 (SPSS Inc., Chicago, Illinois, USA) and presented in the form of mean ± standard deviation (SD), standard error (SE); P < 0.05 was considered statistically significant with confidence interval set at 95%.

Results

Table 3depicts the mean FS and FT (with the corresponding SDs, SEs, and 95% confidence interval upper and lower values) obtained for the Cention N and GIC groups. In comparison between the same groups, the FS and FT of Cention N were statistically highly significant than GIC (Student's t-test; P < 0.00001).{Table 3}

The change in the pH of the lactic acid solution is shown in Table 3. There was a significant difference in the pH of the lactic acid solution at 30 and 60 min of sample immersion. The acid buffer capability of Cention N specimens was significantly higher than that of GIC.

Discussion

The present study compared and evaluated the mechanical properties (fracture strength, FT) and acid buffer capability of Cention N with GIC. Cention N showed significantly higher and better properties than GIC. Hence, the null hypothesis was rejected.

The ability of restorative material to withstand the masticatory loads in stress-bearing areas of Class I, Class II, or IV restorations are crucial for their functional success. 15 The primary reason for failure in the restoration was fracture of restoration when placed in larger cavities over a period longer than 11 years. 18 According to Heintze et al., FT and FS are two valuable tools to characterize the fracture resistance and durability of material under masticatory forces. 19 It is proven that the filler and level of filler weight are directly proportional to the strength of the material. 20 In the present study, Cention N shows a significantly higher FT and FS as compared to GIC. The higher strength can be due to higher filler loading. Cention N has four different dimethacrylates, namely UDMA the main component of the monomer matrix, aromatic aliphatic-UDMA, dicalcium phosphate, and polyethylene glycol 400 dimethacrylate (PEG-400 DMA), representing (PEGDA 400) 21.6% wt. of final mixed material. These filler particles attribute to the high FS and FT 17 , 18 and desired handling characteristics of mixed material.

Various techniques for measuring FT include double torsion, Chevron notch bend specimen, indentation strength, indentation crack length/fracture, double cantilever beam, fractography approach, single-edge precracked beam, single-edge notched (SEN) beam, and compression precracking. The short rod Chevron notch test and the SEN test using rectangular, cylindrical, and prismatic specimens are more common when determining FT of dental materials. 21 The SEN test method to determine the FT was used in this study, primarily because of its simplicity and low cost. FT measurements using a SEN beam use a three- or four-point bending apparatus. The limitations of this test are that the results are sensitive to the width and depth of the notch. This makes direct comparison of the different studies complex. 18

The acid buffer capability of the Cention N and GIC group, 1 week after mixing, when immersed in lactic acid for 30 min and 60 min are depicted in Table 3. The results for Cention N were significantly higher when compared to GIC. This could be due to the regular elution of the fluoride ion from the Cention N compared to the calcium ion from the GIC. 12 , 22 This finding is clinically effective on the premise that Cention N has an acid buffering capacity for up to an hour while being subjected to changes during drinking or eating 16 Although the results obtained in this study suggest efficiency toward caries prevention and remineralization, there is no clinical evidence toward the same.

The results of our study were consistent with the results of studies by Mishra et al., 14 Sadananda et al., 9 Sujith et al., 11 Chole et al., 15 Bahari et al., 5 and Balagopal et al. 12 They reported that Cention N exhibited FS more than GIC and could be used as alternative posterior restorative material.

Limitations of the study are that though we evaluated the acid buffer capability, we could not evaluate the direct effect on caries prevention and remineralization. This is an area for future research. Tribological and ex vivo simulated experiments could yield more exhaustive results for mechanical strength.

Conclusion

The present study showed that the mean FT, FS, and acid buffering capability of Cention N is higher than that of GIC.

Financial support and sponsorship

Nil.

Conflicts of interest

The authors of this manuscript declare that they have no conflicts of interest, real or perceived, and financial or nonfinancial in this article.

Smith DC A new dental cement Br Dent J 381 4 Wilson AD Kent BE A new translucent cement for dentistry.The glass ionomer cement Br Dent J 133 5 Moshaverinia M Navas A Jahedmanesh N Shah KC Moshaverinia A Ansari S Comparative evaluation of the physical properties of a reinforced glass ionomer dental restorative material J Prosthet Dent 154 9 Iftikhar N Devashish Srivastava B Gupta N Ghambir N Rashi-Singh A Comparative evaluation of mechanical properties of four different restorative materials: An in vitro study Int J Clin Pediatr Dent 47 9 Bahari M Kahnamoui MA Chaharom MEE Kimyai S Sattari Z Effect of curing method and thermocycling on flexural strength and microhardness of a new composite resin with alkaline filler Dent Res J (Isfahan) 96 Scientific documentation: Cention N by IvoclarVivadent Ivoclar Vivadent AG Research & Development Scientific Service Bendererstrasse 2 FL – 9494.SchaanLiechtenstein Contents: Joanna-C Todd Issued: October Ivoclar Vivadent AG Research & Development Scientific Service Bendererstrasse 2 FL – 9494 SchaanLiechtenstein Contents: Joanna-C Todd Issued: October 2016 Mann JS Sharma S Maurya S Review article cention N: A review Int J Curr Res 69111 2 Donly KJ Liu JA Dentin and enamel demineralization inhibition at restoration margins of Vitremer, Z 100 and Cention N Am J Dent 166 8 Sadananda V Bhat G Hegde NM Comparative evaluation of flexural and compressive strengths of bulkfill composites Int J AdvSci Res 122 31 Mishra A Singh G Singh SK Agarwal M Qureshi R Khurana N Comparative evaluation of mechanical properties of cention N with conventionally used restorative materials - An in vitro study Int J Prosthodont Restor Dent 120 4 Sujith R Yadav TG Pitalia D Babaji P Apoorva K Sharma A Comparative evaluation of mechanical and microleakage properties of cention-N, composite, and glass ionomer cement restorative materials J Contemp Dent Pract 691 5 Balagopal S Nekkanti S Kaur K An in vitro evaluation of the mechanical properties and fluoride-releasing ability of a new self-cure filling material J Contemp Dent Pract 134 9 Naz F Samad Khan A Kader MA Al Gelban LO Mousa NM Asiri RS Comparative evaluation of mechanical and physical properties of a new bulk-fill alkasite with conventional restorative materials Saudi Dent J 666 73 Gupta N Jaiswal S Nikhil V Gupta S Jha P Bansal P Comparison of fluoride ion release and alkalizing potential of a new bulk-fill alkasite J Conserv Dent 296 9 Chole D Shah HK Kundoor S Bakle S Gandhi N Hatte N In-vitro comparison of flexural strength of cention-N, bulk-fill composites, light-cure nanocomposites, and resin-modified glass ionomer cement IOSR J Dent Med Sci 79 82 Imataki R Shinonaga Y Nishimura T Abe Y Arita K Mechanical and functional properties of a novel apatite-ionomer cement for prevention and remineralization of dental caries Materials (Basel) E3998 Standard AS E 399-90: Standard test method for plane strain fracture toughness of metallic materials.Philadelphia, American Society for Testing and Materials E 399-90: Standard test method for plane strain fracture toughness of metallic materials Philadelphia, American Society for Testing and Materials 1993 Ilie N Hickel R Valceanu AS Huth KC Fracture toughness of dental restorative materials Clin Oral Investig 489 98 Heintze SD Ilie N Hickel R Reis A Loguercio A Rousson V Laboratory mechanical parameters of composite resins and their relation to fractures and wear in clinical trials-A systematic review Dent Mater e101 14 Ersoy M Civelek A L'Hotelier E Say EC Soyman M Physical properties of different composites Dent Mater J 278 83 Soderholm KJ Review of the fracture toughness approach Dent Mater e63 77 Huang CT Blatz MB Arce C Lawson NC Inhibition of root dentin demineralization by ion releasing cements J Esthet Restor Dent 791 6