DRJ Dent Res J Dental Research Journal Dental Research Journal

This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

1735-3327 2008-0255 Wolters Kluwer India Pvt. Ltd. India
DRJ-19-108 10.4103/1735-3327.363567 Review Article Natural teeth wear opposite to glazed and polished ceramic crowns: A systematic review Ghaffari Tahereh Rad Fahimeh H Goftari Afshin Pashazadeh Fariba Ataei Kosar Department of Prosthodontics, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, IranDental Materials Research Center, Health Research Institute, Babol University of Medical Sciences, Babol, IranDentist, Private Practice, Tabriz, IranResearch Center for Evidence Based Medicine, Tabriz University of Medical Sciences, Tabriz, IranDental Student, Faculty of Dentistry, Tabriz University of Medical Sciences, Tabriz, Iran Address for correspondence:Tahereh Ghaffari, Faculty of Dentistry, Tabriz University of Medical Sciences, Golgasht Ave, Tabriz, Iran tahereh_ghaffari@yahoo.com 2022 19 1 108 108 2962020 Copyright: © Dental Research Journal 2022

This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.

It is a major concern to select a proper ceramic with acceptable strength and esthetic and minimum antagonist wear. Therefore, different ceramics were introduced to obtain these advantages with various surface treatments. The aim of this study is to evaluate and report the wear behavior of polished and glazed feldspathic and zirconia crowns in published articles up to 2020. Five electronic databases which were used in this research were MEDLINE (via PubMed), Web of Science, Cochrane Library, Embase, and Scopus from the starting date of databases to January 2020. The Keywords “zirconia,” “feldspathic,” “dental ceramic,” “enamel,” “Y-TZP,” “wear,” “glazed,” and “polished” were used. English articles were selected in this paper. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement was used as a reporting template as much as possible. Among the initially 133 articles, 59 duplicated articles were removed, and finally, 52 articles were screened and among them, only 16 articles remained for full-text regaining. The results showed that zirconia had significantly less antagonist wear than feldspathic groups, and polishing had less enamel wear than other types of surface treatment like glazing. Only one study showed that glazed zirconia can have more antagonist wear than feldspathic porcelain. Monolithic zirconia had less enamel wear than conventional zirconia and low-fusing feldspathic porcelain showed lower antagonist wear in comparing with other types of feldspathic porcelains.

Dental enamel dental porcelain dental wear feldspathic porcelain In-Ceram zirconia review Y-TZP ceramic
</sec><sec><title>Introduction

Antagonist tooth wear is considered one of the significant problems when using dental ceramics. It is complex and multifactorial process which has some functional and esthetic complications.1,2 The complexity of tooth wear process makes it difficult to conduct adequate clinical studies on this issue; therefore, in vitro studies using wear-simulator machines which simulate oral conditions in controlled-experimental way were introduced in 1996.3,4,5 These machines can reduce confounding variables such as pH, review viscosity, and flow rate of the saliva that affects enamel wear.6

Determining a dental ceramic that simultaneously has enough strength without the disadvantage of increased enamel wear, has important clinical role in prosthodontics and the science of dental materials.7,8 Some studies showed that the amount of antagonist enamel wear opposing dental ceramics is strongly material dependent.9,10 For example, Stawarczyk et al. showed that conventional zirconia resulted in significant higher antagonist wear than monolithic zirconia9 and Rosentritt et al. concluded that feldspathic porcelains provided higher wear than zirconia specimens.10

Because of increasing patient's demands for having more dental esthetic,11 veneered zirconia porcelains have been widely used because of their excellent esthetic and mechanical properties,12,13 however, high wear rate of their antagonist teeth have been reported by many in vitro studies.14,15,16 In order to reduce enamel wear of veneered zirconia, translucent, and no veneered zirconia porcelains have been established.17,18

The wear behavior of zirconia has not been understood completely.19,20 Many studies have evaluated the effects of different polishing and glazing techniques on the enamel wear opposing dental porcelains.2,21,22

Since there is a controversy about the effect of different ceramic systems on the wear of enamel because of different environmental and testing conditions, this systematic review was undertaken to evaluate and report the wear behavior of polished and glazed feldspathic and zirconia crowns in published articles up to January 2020.

Materials and Methods

This systematic review was Performed Using the Preferred Reporting Items for Systematic Reviews and Meta-Analyses statement.23

Inclusion criteria

Participants

Studies assessing tooth wear process in the experimental condition.

Intervention

Studies using Y-TZP zirconia.

Comparison

Studies comparing feldspathic porcelain with Y-TZP zirconia

Outcomes

Studies which evaluated the antagonist's enamel or steatite.

Types of studies

All in vitro studies were included in this review.

Studies published in English and published the starting date of databases to January 2020 were considered for inclusion in this review.

Exclusion criteria

(1) Incomplete data reporting, (2) systematic review articles, (3) absence of enamel wear evaluation or steatite wear evaluation, (4) use of veneered zirconia, (5) absence of clear method/materials, (6) in vivo studies, (7) high bias articles, (8) case reports, and (9) conference papers were excluded from the study.

Search strategy

A systematic search of electronic databases was conducted on Web of Science, MEDLINE (via PubMed), Cochrane Library, EMBASE, and Scopus. Additional hand searching was conducted through the references of included studies. In the primary search, the terms used were “dental ceramic,” “enamel,” “wear,” and “feldspathic,” “zirconia,” “Y-TZP,” “polished,” and “glazed.” No publication year limits were applied during the electronic searches. English articles were selected in this paper. The search strategies in PubMed, Embase, and Scopus are presented in Appendix I.

Study selection

Related titles and abstracts were screened by two independent reviewers and articles without an available abstract were excluded. Discrepancies between two reviewers were solved by discussion. The Cohen's Kappa value was used for inter-observer reliability and it should be greater than 80%. In case of unsolved disagreements, the third reviewer decided to include the article or not. After appraising of abstracts, potentially eligible articles were regained in full text.

Assessment of methodological quality

Methodological quality regarding the risk of bias in selected articles was assessed by one of the authors according to the criteria as set by the Cochrane collaboration's tool.24 Allocation concealment was not applicable for this systematic review and therefore its column was removed Table 1. A meta-analysis could not be performed, as the test parameters differed from one study to the other. Therefore, the results of included studies were descriptively reported and discussed.{Table 1}

The information extracted from the articles is summarized in Table 2.{Table 2}

Results

One hundred and thirty-two articles were identified through electronic database searching and one article was found through hand-searching by checking the references of included articles. Among the initially 133 articles, 59 duplicated articles were removed, and finally, 52 articles were screened and among them, only 16 articles remained for full-text regaining and 11 studies were excluded for inappropriate study design, intervention, and outcome Figure 1.

Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagram of the selection process.

Figure 1

There was a great variation of wear-simulator properties among studies as shown in Table 2 along with other information extracted from the articles. The wear simulator types among included studies were: UAB chewing simulator, Alabama wear testing device, Custom-made chewing simulator of Zurich university, pin-on-block wear tester, chewing simulator (SD mechatronik), two-body wear machine, pin-on-disk or pin-on-plate, and dual-axis chewing simulator which they were used to mimic human-controlled oral conditions to observe antagonist's wear opposite to zirconia and feldspathic porcelains. The wear-body of experiments were in two models: 2-Body wear and 3-Body wear, which in 2-Body wear, there was no liquid mediator between porcelains and antagonists, and in 3-Body wear, there was mediators such as distilled water, glycerin, or artificial saliva. 3-Body wear simulators supposed to have a better simulation of oral conditions because of the existence of human natural saliva. The range of cycles of wear between simulators was 5000 and 1200,000 cycles and their frequencies were between 0.8 and 20 Hz. The range of loading force used to mimic masticatory force was in a range of 0.6–100 N. Antagonists consist of two types: human natural teeth (upper and lower premolar and molars) and industrial simulated enamel (Steatite).

Among included studies, six studies showed that zirconia groups had significantly less antagonist wear than feldspathic groups,9,10,14,15,16,25 and among the different surface treatments, polishing had less enamel wear than other types of surface treatment like glazing.15,26,27,28,29,30,31 Only one study showed that glazed zirconia can have more antagonists wear than feldspathic porcelain.26 Monolithic zirconia had less enamel wear than conventional zirconia9 and low-fusing feldspathic porcelain showed lower antagonist wear in comparing with traditional feldspathic porcelains but there was no significant difference between the enamel wear of two low-fusing porcelains.32 A study conducted by Stawarczyk et al. showed that although polished monolithic zirconia showed lower wear rate on enamel antagonists, it developed higher rates of enamel cracks30 Table 3.{Table 3}

There were different brands of zirconia and feldspathic specimens which are listed in Table 4. Wear evaluators were in four types: scanning electron microscope (SEM), confocal microscopy, digital micrometer, white light interferometer, which they report amount of antagonist's wear in three Types: (1) Vertical wear (μm), (2) Area wear (mm2), and (3) Volumetric wear (mm3) Table 4.{Table 4}

Discussion

Among studies which were critically appraised in this systematic review, 16 were in low level of bias risks, remains were high risks. Near 78% of these studies were free of reporting and other biases and almost 60% had adequate sequence generation, but in 60% of studies, there were incomplete outcome data. In addition, blinding was not applicable in these study designs. The first and second null hypotheses of this study stating that there is no difference in the wear number of antagonists of zirconia and feldspathic specimens, and glazing and polishing techniques do not affect antagonist's wear of zirconia and feldspathic groups. The findings of this study rejected both hypotheses with the following reasons:

One of the reasons that can explain lower antagonist wear of zirconia comparing with feldspathic porcelains is zirconia's smaller particle (fine grain) which can result in smoother and monotonic surface. Another reason is higher fracture toughness of zirconia (9 MPa) comparing with feldspathic porcelain (0.73 MPa). Low fracture toughness of feldspathic porcelain can lead to microfractures on its surface which results in prominences and roughness. This increasing roughness makes stress on enamel antagonist and leads to abrasion.33

High fracture toughness in Y-TZP zirconia may be explained by phase transformation from the tetragonal to monoclinic phase due to external pressure, which leads to a volume expansion of about 3%–5%. It creates compressive strength and prevents cracks spreading and therefore makes it less surface roughness.34

Glazed zirconia showed greater wear compared with polished zirconia, although the surface of glazed zirconia results in smooth, esthetic, and hygienic surface but the glaze layer can be easily removed during function or occlusal adjustment, and the underlying rough ceramic surface exposed and can cause aggressive damage of enamel antagonists.15,26,27,28,29,30,31,35 In some in vivo studies the wear behavior of glazed and polished zirconia prostheses are comparable.36,37,38 SEM images of polished zirconia showed a surface with a more fine-grained and homogeneous texture, therefore polishing techniques decrease the surface roughness of zirconia and subsequently the wear of natural antagonists.27

The low wear rate of enamel antagonist to monolithic zirconia comparing with conventional ones can be explained by lower mechanical properties of this material.9

Clinical studies demonstrated disputed wear manners of monolithic zirconia crowns, that some resulted similarity36,37,38 or greater39,40 wear of natural teeth antagonist in compare to enamel-enamel tooth contact.

Although it is a common perception that hardness of a material is directly proportional to its abrasiveness, several studies have shown that hardness alone cannot explain the abrasive properties of a substance.11 It seems that the wear of a material is more related to the level of its surface roughness than the hardness, and therefore various studies suggest that surface roughness of porcelain is important factor to predict antagonist wear of porcelains.41,42 Physical grain or crystal size plays an important role in the surface topography and roughness of porcelains, too.

Lohbauer and Reich evaluated the amount of wear on the antagonist occlusal surfaces of clinically placed monolithic zirconia premolar and molar crowns (LAVA Plus, 3M ESPE). They showed mean wear of 200 μm as admissible. The monolithic zirconia crowns (LAVA Plus) showed acceptable antagonist wear rates after 2 years in situ, regardless of natural enamel or ceramics as antagonist materials;43 and of course, monolithic zirconia crowns are well known with low amount of antagonist wear when opposed to monolithic zirconia itself.44

The result of Habib et al. investigation showed monolithic zirconia has more wear effect to natural teeth in comparison to lithium disilicate and composite resin.45 Pereira et al. demonstrated that the wear of composite resin opposed to monolithic zirconia is greater than opposing bovine enamel.46 Gundugollu et al. conducted that glazed polished monolithic zirconia produce more wear of the opposed enamel in comparison to unglazed polished monolithic zirconia.47

The results of Esquivel-Upshaw et al. investigation showed that polished monolithic zirconia (Lava Plus) has a similar amount of wearing of opposing enamel to metal-ceramic and enamel antagonists.38

Low-fusing feldspathic porcelains showed lower antagonist wear in comparing with traditional feldspathic porcelains but there was no significant difference between the enamel wear of two low-fusing porcelains.32 These results can be described by large grain particle size of traditional feldspathic porcelain which contributes to a much more irregular surface and therefore an increase in abrasive qualities. The similarity between surface roughness of two low-fusing porcelains can explain the same wear amount of their antagonists.14,25,32

Human enamel has been considered the best choice for wear studies, however, there are some complications to using them such as natural variations in shape and physical properties, and therefore natural teeth require extensive preparation and standardization which can be difficult due to their variations. Some studies used industrial hydroxyapatite called steatite as a substrate for human natural enamel and showed that it can be a reliable substrate in wear studies instead of human natural teeth.26,29 Wear measurement of steatite opposed to zirconia and feldspathic groups revealed the same results as enamel specimens.10

We suggest to researchers to use steatite in further wear studies because it allows the standardization of antagonistic conditions, however, it has some differing mechanical properties such as higher hardness (steatite: 680 HV; enamel: 330 HV) or initial roughness (steatite: 1.7 μm, enamel: 0.9 μm).30

The wear behavior of ceramics in clinical practice is a combination of 2-Body and 3-Body wear, but evaluation of methods of included studies showed that they use either 2-Body or 3-Body wear simulator, and none of them use combination of them to simulate oral conditions near to reality.27,28,48 It should be noted that 3-Body wear may reduce the effect of surface roughness due to the presence of a third body, and therefore selecting a proper liquid mediator such as artificial saliva should be considered.26

There are two common methods for decreasing roughness, glazing, and polishing. The amount of roughness is related to use polishing system it would be between 0.08 and 0.9 mm. The roughness of polished zirconia is approximate to glazed one.49

Different finishing and polishing procedures for zirconia specimens affected antagonistic enamel wear, vertically and volumetrically;50 although there was no significant difference in antagonist wear of feldspathic porcelains by different polishing techniques.14 This observation can be explained by their different microstructure and surface properties. It should be noted that not all materials can be made smoothed. Large grain porcelains such as feldspathic porcelains are the good samples of these materials.14,15,32 Different glazing techniques can cause significantly different antagonists wear of zirconia groups. For example, using of glaze spray (GS) made significantly less enamel's wear than using glaze ceramic (GC). Both GC and GS can provide a thin smooth layer in comparison with unglazed zirconia, but their glaze layer will be worn in a short period, approximately after 6 months under clinical conditions. SEM analysis showed that after removing the glaze layer, the surface under GS was smoother than GC, therefore results in low enamel wear.9,30,51

The zirconia materials show similar composition, but differ in sintering temperature and resulting grain sizes. Especially sintering conditions may influence microstructure, longevity and hydrolytic performance, and finally, wear behavior of material.9,14,16

The zirconia or feldspathic specimens should be polished before any surface treatment because when the staining becomes worn, a rough surface may accelerate wear.15,16,31 Finally, this systematic review recommends using polished monolithic zirconia to reduce antagonist wear in clinical practice.

Conclusion

Under the limitations of the present study, there was a significant difference between antagonist wear of zirconia and feldspathic specimens among included studies, which zirconia specimens showed wear-friendly behavior than feldspathic ones, and also among different surface treatments, polishing leads to less enamel wear than glazing.

Financial support and sponsorship

This article is funded Tabriz University of Medical Sciences, Tabriz, Iran.

Conflicts of interest

The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or nonfinancial in this article.

56

Ramp MH Ramp LC Suzuki S Vertical height loss: An investigation of four restorative materials opposing enamelJ Prosthodont 252 7 Elmaria A Goldstein G Vijayaraghavan T Legeros RZ Hittelman EL An evaluation of wear when enamel is opposed by various ceramic materials and goldJ Prosthet Dent 345 53 Mair LH Stolarski TA Vowles RW Lloyd CH Wear: Mechanisms, manifestations and measurement.Report of a workshopJ Dent 141 8 Ramalho A Miranda J The relationship between wear and dissipated energy in sliding systemsWear 361 7 Lee A Swain M He L Lyons K Wear behaviour of human enamel against lithium disilicate glass ceramic and type III goldJ Prosthet Dent 1399 405 Heintze SD How to qualify and validate wear simulation devices and methodsDent Mater 712 34 Mulay G Dugal R Buhranpurwala M An evaluation of wear of human enamel opposed by ceramics of different surface finishesJ Indian Prosthodont Soc 111 8 Khandelwal M Jain D A comparative evaluation of wear of enamel caused by ceramics with different fusion temperaturesJ Indian Prosthodont Soc 513 9 Stawarczyk B Frevert K Ender A Roos M Sener B Wimmer T Comparison of four monolithic zirconia materials with conventional ones: Contrast ratio, grain size, four-point flexural strength and two-body wearJ Mech Behav Biomed Mater 128 38 Rosentritt M Preis V Behr M Hahnel S Handel G Kolbeck C Two-body wear of dental porcelain and substructure oxide ceramicsClin Oral Investig 935 43 Ahmadzadeh A Ashtiani AH Epakchi S Golmohamadi F Mousavi N Pormehdi M Comparison of the effect of feldspathic porcelain and zirconia on natural tooth wearJ Islam Dent Assoc IRAN 170 6 Etman MK Woolford M Dunne S Quantitative measurement of tooth and ceramic wear: In vivo studyInt J Prosthodont 245 52 Esquivel-Upshaw J Rose W Oliveira E Yang M Clark AE Anusavice K Randomized, controlled clinical trial of bilayer ceramic and metal-ceramic crown performanceJ Prosthodont 166 73 Kim MJ Oh SH Kim JH Ju SW Seo DG Jun SH Wear evaluation of the human enamel opposing different Y-TZP dental ceramics and other porcelainsJ Dent 979 88 Janyavula S Lawson N Cakir D Beck P Ramp LC Burgess JO The wear of polished and glazed zirconia against enamelJ Prosthet Dent 22 9 Park JH Park S Lee K Yun KD Lim HP Antagonist wear of three CAD/CAM anatomic contour zirconia ceramicsJ Prosthet Dent 20 9 Kern M Clinical long-term survival of two-retainer and single-retainer all-ceramic resin-bonded fixed partial denturesQuintessence Int 141 7 Ghazal M Kern M The influence of antagonistic surface roughness on the wear of human enamel and nano-filled composite resin artificial teethJ Prosthet Dent 342 9 DeLong R Douglas WH Sakaguchi RL Pintado MR The wear of dental porcelain in an artificial mouthDent Mater 214 9 Baldissara P Llukacej A Ciocca L Valandro FL Scotti R Translucency of zirconia copings made with different CAD/CAM systemsJ Prosthet Dent 6 12 Kou W Molin M Sjögren G Surface roughness of five different dental ceramic core materials after grinding and polishingJ Oral Rehabil 117 24 Saraç D Turk T Elekdag-Turk S Saraç YS Comparison of 3 polishing techniques for 2 all-ceramic materialsInt J Prosthodont 465 8 Moher D Liberati A Tetzlaff J Altman DG; Prisma Group Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statementPLoS Med e1000097 Cumpston M Li T Page MJ Chandler J Welch VA Higgins JP Updated guidance for trusted systematic reviews: A new edition of the Cochrane Handbook for Systematic Reviews of InterventionsCochrane Database Syst Rev ED000142 Jung YS Lee JW Choi YJ Ahn JS Shin SW Huh JB A study on the in-vitro wear of the natural tooth structure by opposing zirconia or dental porcelainJ Adv Prosthod 111 5 Bai Y Zhao J Si W Wang X Two-body wear performance of dental colored zirconia after different surface treatmentsJ Prosthet Dent 584 90 Sabrah AH Cook NB Luangruangrong P Hara AT Bottino MC Full-contour Y-TZP ceramic surface roughness effect on synthetic hydroxyapatite wearDent Mater 666 73 Rupawala A Musani SI Madanshetty P Dugal R Shah UD Sheth EJ A study on the wear of enamel caused by monolithic zirconia and the subsequent phase transformation compared to two other ceramic systemsJ Indian Prosthodont Soc 8 14 Kontos L Schille C Schweizer E Geis-Gerstorfer J Influence of surface treatment on the wear of solid zirconiaActa Odontol Scand 482 7 Stawarczyk B Özcan M Schmutz F Trottmann A Roos M Hämmerle CH Two-body wear of monolithic, veneered and glazed zirconia and their corresponding enamel antagonistsActa Odontol Scand 102 12 Lawson NC Janyavula S Syklawer S McLaren EA Burgess JO Wear of enamel opposing zirconia and lithium disilicate after adjustment, polishing and glazingJ Dent 1586 91 Metzler KT Woody RD Miller AW 3rd Miller BH In vitro investigation of the wear of human enamel by dental porcelainJ Prosthet Dent 356 64 Firooz F Heidari B Vafaei F Soltanian A Bakhshi H Mehr S Association between enamel abrasion and surface roughness of dental ceramicsJ Mash Dent Sch 51 60 Özkurt Z Monolithic zirconia: A review of the literatureJ Biomed Res 1427 36 Kaizer MR Zhang Y Novel strong graded high-translucency zirconias for broader clinical applicationsDent Mater e140 1 Hartkamp O Lohbauer U Reich S Antagonist wear by polished zirconia crownsInt J Comput Dent 263 74 Zhang Y Lawn BR Novel zirconia materials in dentistryJ Dent Res 140 7 Esquivel-Upshaw JF Kim MJ Hsu SM Abdulhameed N Jenkins R Neal D Randomized clinical study of wear of enamel antagonists against polished monolithic zirconia crownsJ Dent 19 27 Mundhe K Jain V Pruthi G Shah N Clinical study to evaluate the wear of natural enamel antagonist to zirconia and metal ceramic crownsJ Prosthet Dent 358 63 Stober T Bermejo JL Schwindling FS Schmitter M Clinical assessment of enamel wear caused by monolithic zirconia crownsJ Oral Rehabil 621 9 Burgess JO Janyavula S Lawson NC Lucas TJ Cakir D Enamel wear opposing polished and aged zirconiaOper Dent 189 94 Mörmann WH Stawarczyk B Ender A Sener B Attin T Mehl A Wear characteristics of current aesthetic dental restorative CAD/CAM materials: Two-body wear, gloss retention, roughness and Martens hardnessJ Mech Behav Biomed Mater 113 25 Lohbauer U Reich S Antagonist wear of monolithic zirconia crowns after 2 yearsClin Oral Investig 1165 72 D'Arcangelo C Vanini L Rondoni GD Vadini MD Wear evaluation of prosthetic materials opposing themselvesOper Dent 38 50 Habib SR Alotaibi A Al Hazza N Allam Y AlGhazi M Two-body wear behavior of human enamel versus monolithic zirconia, lithium disilicate, ceramometal and composite resinJ Adv Prosthodont 23 31 Pereira GK Dutra DM Werner A Prochnow C Valandro LF Kleverlaan CJ Effect of zirconia polycrystal and stainless steel on the wear of resin composites, dentin and enamelJ Mech Behav Biomed Mater 287 93 Gundugollu Y Yalavarthy RS Krishna MH Kalluri S Pydi SK Comparison of the effect of monolithic and layered zirconia on natural teeth wear: An in vitro studyJ Indian Prosthodont Soc 336 Chong BJ Thangavel AK Rolton SB Guazzato M Klineberg IJ Clinical and laboratory surface finishing procedures for zirconia on opposing human enamel wear: A laboratory studyJ Mech Behav Biomed Mater 93 103 Mohammadi-Bassir M Babasafari M Rezvani MB Jamshidian M Effect of coarse grinding, overglazing, and 2 polishing systems on the flexural strength, surface roughness, and phase transformation of yttrium-stabilized tetragonal zirconiaJ Prosthet Dent 658 65 Mitov G Heintze SD Walz S Woll K Muecklich F Pospiech P Wear behavior of dental Y-TZP ceramic against natural enamel after different finishing proceduresDent Mater 909 18 Beuer F Stimmelmayr M Gueth JF Edelhoff D Naumann M In vitro performance of full-contour zirconia single crownsDent Mater 449 56 Bartolo D Cassar G Al-Haj Husain N Özcan M Camilleri J Effect of polishing procedures and hydrothermal aging on wear characteristics and phase transformation of zirconium dioxideJ Prosthet Dent 545 51 Hacker CH Wagner WC Razzoog ME An in vitro investigation of the wear of enamel on porcelain and gold in salivaJ Prosthet Dent 14 7 Magne P Oh WS Pintado MR DeLong R Wear of enamel and veneering ceramics after laboratory and chairside finishing proceduresJ Prosthet Dent 669 79 Preis V Behr M Handel G Schneider-Feyrer S Hahnel S Rosentritt M Wear performance of dental ceramics after grinding and polishing treatmentsJ Mech Behav Biomed Mater 13 22 Preis V Schmalzbauer M Bougeard D Schneider-Feyrer S Rosentritt M Surface properties of monolithic zirconia after dental adjustment treatments and in vitro wear simulationJ Dent 133 9

Refbacks

  • There are currently no refbacks.