This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Zinc oxide (ZnO) and graphene oxide (GO) nanoparticles (NPs) have antimicrobial properties. The present study was undertaken to evaluate the effects of incorporating these NPs and their chemical and physical blends on abrasion, translucency, and microhardness of flowable composite resin.
In the present in vitro study, flowable composite resin samples (Grandio Flow, VOCO, Germany) were evaluated in 5 groups and the sample size was 10 for each group of each experiment (n = 10) as follows: Group 1, without NPs; Group 2, with ZnO NPs; Group 3, with GO NPs; Group 4, containing a physical mixture of GO and ZnO; and Group 5, containing a chemical mixture of GO and ZnO NPs. In all the groups, 1 wt% of the NPs were incorporate into flowable composite resin. Abrasion, translucency, and microhardness of the samples were evaluated. Data were analyzed with analysis of variance, followed by post hoc Tukey's tests at the level of significance of P < 0.05. In the present in vitro study, flowable composite resin samples (Grandio Flow, VOCO, Germany) were evaluated in 5 groups and the sample size was 10 for each group of each experiment (n = 10) as follows: Group 1, without NPs; Group 2, with ZnO NPs; Group 3, with GO NPs; Group 4, containing a physical mixture of GO and ZnO; and Group 5, containing a chemical mixture of GO and ZnO NPs. In all the groups, 1 wt% of the NPs were incorporate into flowable composite resin. Abrasion, translucency, and microhardness of the samples were evaluated. Data were analyzed with analysis of variance, followed by post hoc Tukey's tests at the level of significance of P < 0.05. In Groups 2, 4, and 5 (all the groups containing ZnO), a significant decrease in abrasion and microhardness of flowable composite resin was observed compared to the control group. Incorporation of NPs in all the groups resulted in a significant decrease in translucency compared to the control group. Incorporation of NPs into flowable composite resin resulted in a decrease in translucency. The microhardness was reduced in groups containing ZnO, but the abrasion was also reduced in these groups. The incorporation of GO did not significantly alter the abrasion and microhardness of the composite resin.
Dental caries is the most common chronic childhood disease. The occlusal surface of teeth has some pits and fissures that are the most susceptible areas for the initiation and progression of caries. Recent studies have shown that almost 90% of caries in the permanent teeth of children occur in pits and fissures and two-thirds of caries occur only on the occlusal surfaces of teeth.
Preventive resin restoration is the most conservative treatment option for the restoration of pit and fissure caries and for the prevention of caries in caries-prone pits and fissures in young permanent teeth.
Conventionally, occlusal abrasion has been the most prevalent problem of posterior composite resins. Although it appears larger particles have higher hardness, it has been shown that larger particles accelerate abrasion. Therefore, in recent years, nanoparticles (NPs) have been introduced as fillers.
For many decades, metallic oxide particles have been used as antibacterial agents in composite resins to decrease the rate of recurrent caries.
Graphite NPs, which consist of carbon nanotubes, fullerene, and graphene, are considered promising agents due to their innovative properties, including antibacterial activity.
However, the main limitation of graphene compounds as antimicrobial agents in dentistry is their gray color and their tendency to form agglomerations when they are dispersed in a colloidal suspension. Therefore, although incorporation of GO into dental composite resins might result in an antibacterial activity,
Considering the importance of the issues discussed above, the present study was designed to evaluate the effects of incorporating ZnO and GO NPs separately and together into flowable composite resin (Grandio) on abrasion, translucency, and microhardness of these composite resins. The null hypothesis is that examined materials have not to effect on physical and mechanical properties of composite resin.
This in vitro study with the code of ethics IR.MUBABOL.HRI.REC.1397.206 was registered in the Research Institute of Health, Babol University of Medical Sciences.
Preparation of materials
In this in vitro study, spherical ZnO NPs, measuring 20 nm (MERCK, Germany) and layered GO NPs, with a mean size of 3.4–7 nm (MERCK, Germany) were used for mixing 0.5 wt% of ZnO with 0.5 wt% of GO.
First, for physical mixing, the ZnO solution was dissolved in methanol and chloroform and then mixed with the alcoholic solution of GO for 24 h. Then, the samples were separated with the use of solvent propagation technique in a centrifugation unit. The solvent was evaporated and the resultant precipitate was dried in an oven.
To prepare the chemical mixing, first, the ZnO NPs were dissolved in dimethyl sulfoxide solvent with the use of aminopropyltriethoxysilane, followed by agitation with the use of the ultrasonic technique. Then, the resultant precipitate was rinsed with ethanol and collected with the use of a centrifugation unit. A certain amount of the resultant precipitate was added to the GO solution in dimethylformamide solvent and allowed to take part in the chemical reaction. The chemical blend was achieved with the use of an ultrasound unit for 2 h using the purification technique with alcohol and drying in an oven.
Preparation of specimens
Grandio flow composite resin (VOCO, Germany) shade A2 was selected for this study. One wt% from NPs with a digital scale with 0.0001 accuracies (AC Adapter, Japan) was weighed and manually with spatulation for 15 min in red-light condition on vibrator was mixed with composite resin so that homogeneity obtained.
Hence, study groups including:
Control group (without adding NP) Containing 1 wt% ZnO NP Containing 1 wt% GO Containing 1 wt% physical compound of ZnO and GO Containing 1 wt% chemical compound of ZnO and GO.
EDAX analysis
X-ray photoelectron spectroscopy (XPS, PHI-5702, Physical Electronics) was used to analyze homogeneity and purity percentage and level percent of materials on the surface of specimens by Al-Ka radiation as the excitation source and the bonding energy of Au (Au 4f7/2: 84.00 eV) as reference.
Abrasion test
To carry out this test, 10 samples were fabricated for each group in the form of a cube (measuring 2 mm × 10 mm × 10 mm) in a transparent mold. The samples were light-cured using a bluephase C8 (Ivoclar Vivadent) light-curing unit for 20 s. After preparation of the samples, they were stored in distilled water at room temperature for 24 h for maximum water sorption. Before abrading, the samples were thoroughly cleaned and dried. The weight of each sample was determined with the use of a digital weighing machine (AC Adapter) accurate up to 0.0001 g. The samples were placed separately in an abrading machine (PEDEB1, Babol Dentistry Research, Iran). The chrome-cobalt abrader of this machine has a cross-section of 1.12 mm2, which delivered a 2-kg force at 5000, 10,000, 20,000, 40,000, 80,000, and 120,000 abrasion cycles on the samples. At the end of each abrasion cycle, the samples were thoroughly cleaned, dried, and weighed again. This way the amount of abrasion was determined.
Translucency test
To carry out this test, 10 composite resin disk-shaped samples were fabricated for each group, which measured 10 mm in diameter and 2 mm in thickness. All the samples were polished with the use of Soflex (3M, American) polishing disks to remove the resin-rich layer. To determine l, a and b parameters, the samples were exposed to standard D65 light in a special chamber using the easy shade machine (Vita, Germany) on a standard white and black background. The machine was calibrated before each measurement procedure. The translucency parameters were calculated and placed in the following formula:
ΔE = ([lW–lB] 2+ [aW–aB] 2+ [bW–bB] 2) 1/2
Where W and B represent the data acquired with the use of the white and black background, respectively.
Microhardness test
To carry out this test, the samples used in the translucency test were stored in distilled water at room temperature under dark conditions for 24 h. Then, they were mounted in epoxy resin and divided into two halves with the use of a disk. Then, the cut surfaces were completely polished with 400-, 800-, 1000-, 1500-, 2000-, and 2500-grit silicon carbide paper (3M, American). Then, the microhardness of the cut surfaces was determined from the surface up to the depth of the samples at 0, 0.5, 1, 1.5, and 2 mm intervals using a Vickers hardness testing machine (MH2, KOOPA Company, Iran) 3 times and their means were recorded. The force applied by the machine was 500 g, which was applied for 10 s.
Statistical analysis
The statistics consultant determined the sample size based on similar articles. One-way analysis of variance (ANOVA) followed by Tukey's post hoc comparison test was used to test the differences between control and experimental groups at the level of significance of P < 0.05 with SPSS 16 (SPSS. Inc., Chicago, IL, USA).
EDAX analysis
Energy-dispersive X-ray spectroscopy elemental analysis is shown in
Abrasion
Abrasion in the GO group was not significantly different from that in the control group, except for the 10,000-round cycle in which abrasion in this group was significantly lower than that in the control group. ANOVA showed significant differences in abrasion between the study groups. Based on the results of Tukey's tests, incorporation of ZnO NPs and physical and chemical mixtures in all the cycles resulted in a significant decrease in abrasion compared to the control group
According to the abrasion graph in the different cycles, two composite groups are observed; the first group is related to the control group and contains GO, which shows more abrasion. The second group is related to the ZnO-containing groups (Groups 2, 4, and 5) that show less abrasion. ZnOs presence in the composite resin seems to reduce its abrasion. This theme is not visible in the GO group [Graph 1].[INLINE:1]
Translucency
ANOVA revealed significant differences in translucency between the study groups. Based on the results of Tukey's tests, incorporation of NPs into composite resin structure in all the groups resulted in significant decreases in translucency compared to the control group
Microhardness
ANOVA showed significant differences in microhardness between all the groups. Based on the results of Tukey's tests, at depth 0 and 0.5 mm, the microhardness of the ZnO group was significantly lower than that of other groups. Incorporation of ZnO NPs and the physical compound resulted in a significant decrease in microhardness compared to the control group at 1, 1.5, and 2 mm depths. Microhardness in the GO and chemical compound group was not significantly different from the control group
It is obvious that antimicrobial properties are very important and useful for composite resins used for restorative purposes, especially in children. One of the techniques to confer antimicrobial properties to composite resins is to incorporate some particles into their structure.
The aim of this study was to investigate the effect of adding ZnO and GO NPs on abrasion, translucency, and microhardness flowable composite resin in vitro. According to searches, no similar study has been found so far.
An in vitro study cannot simulate all the conditions of the oral cavity. On the other hand, clinical studies on the abrasion of restorative materials are time consuming, costly, and more complicated than in vitro studies in relation to the procedural steps. Therefore, the present study was evaluated in vitro.
There are several ways to estimate of abrasion resistance. In the present study, the weight loss method was used.
Various studies have reported that the abrasion rate of flowable composite resin is higher than other composites. Clelland et al. reported that flowable composite reins exhibited more abrasion compared to the highly filled composite resins in the microfilled and microhybrid categories.
Recent studies have shown that it is possible to improve the physical properties of flowable composite resins by increasing in volume and decreasing in size of the filler content.
The results of the present study showed that incorporation of ZnO NPs, physical mixture, and chemical blend resulted in a decrease of abrasion in all the cycles; however, the amount of abrasion in the GO group did not differ significantly from the control group and was lower in the 10,000 cycle alone. The presence of ZnO NPs in these groups (ZnO groups, physical composition, and chemical composition) seems to have reduced abrasion. GO particles have a layered structure, and the lack of adhesion between the GO layers and the composite resin may not increase the abrasion resistance of the composite resin.
The reasons for a decrease in abrasion might be attributed to factors such as the type of matrix and resin, the size, shape and distribution of filler particles, silanization, hardness of the filler, and degree of conversion of composite resins.
Based on previous studies, the filler content of composite resins affects abrasion. The filler content has an indirect relationship with abrasion and an increase in filler content results in a decrease in abrasion, which might be explained by a lower surface area of the resin unprotected by filler particles.
In the present study, the colorimetry technique with the use of a spectrophotometer was applied to determine color changes. In addition, since based on the objective CIELAB system, the l, a and b parameters are suitable for research studies and for quantitative evaluation of color changes;
In the present study, translucency in the GO, the physical and chemical composition compared to the control group were >3.3 and in the ZnO group, it was <3.3. Therefore, only in the ZnO group could not be detected changes in translucency by the eyes of laypeople (ΔEControl – ΔEZnO = 2.8).
Brandão et al. reported that the translucency of composite rein containing ZnO NPs depends on the concentration, decreasing with an increase in concentration. Therefore, translucency is negatively affected by ZnO NPs. An increase in the concentration of ZnO NP concentration resulted in a decrease in the degree of conversion of the tested adhesives. Most probably, a decrease in the translucency of composite reins with a higher ZnO-NP contact is due to the dissimilarity between the fracture index of Bis-GMA: TEGDMA complex and ZnO-Np.
Hardness is an internal property of materials and depends on the composition and microstructure of the material. In addition, it should be noted that an increase in filler quality does not necessarily result in an increase in hardness because hardness depends on other factors including the type and quality of silanization and modification of the filler surface, too.
In the present study, incorporation of GO NPs into flowable composite resin resulted in an increase in microhardness compared to the control group, which was not significant.
Sava et al. reported that incorporation of 5–10 wt% of a mixture of hydroxyapatite and GO NPs into the matrix monomer of composite resin resulted in an increase in surface hardness, young modulus, and flexural strength.
In the present study, incorporation of ZnO NPs and a physical mixture of NPs into flowable composite resin resulted in a significant decrease in microhardness compared to the control group. Panahandeh et al. reported that incorporation of nanorod ZnO particles did not result in any change in the surface hardness of glass ionomer; however, incorporation of nanospherical and nanoflower ZnO particles resulted in a significant decrease in surface hardness of glass ionomer compared to the control group.
Tavassoli et al. showed that incorporation of ZnO NPs into flowable composite resin resulted in improvements in its compressive strength, flexural module, and bond strength, in addition to its antibacterial properties, with no effect on flexural strength and compressive module.
Considering a paucity of studies on the physical and mechanical properties of composite resins containing GO and ZnO NPs, further studies are necessary to evaluate the effects of these NPs on other mechanical and physical properties of flowable composite resin.
Incorporation of NPs into flowable composite resin resulted in a decrease in translucency. The microhardness was reduced in groups containing ZnO, but the abrasion was also reduced in these groups. The incorporation of GO did not significantly alter the abrasion and microhardness of the composite resin.