This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
Visual and advanced instrumental methods are the most common tools for shade selection. The instrumental methods are considered reliable and provide quantifiable values, but the high cost puts them out of the reach of most dentists. Light-correcting devices provide an economical alternative for clinical shade selection. The aim of this study was to assess the reliability of the light-correcting device in clinical shade selection.
The in vivo experimental prospective study sample included 60 volunteers aged 18–25 years, with no severe enamel pigmentation or anomaly in anterior maxillary teeth. Two observers performed visual shade matching of the maxillary right central incisor without a light-correcting device and later with a light-correcting device at the same time of the day at an interval of 1 week. The shades were confirmed with the control value obtained by using a spectrophotometer. Each observer was blinded to the shade color selected by the other examiner. The data collected were subjected to the statistical analysis. The shade measured with the light-correcting device and without its use was compared with the control shade obtained by the spectrophotometer. The value closer to the control shade value was considered accurate, and the method used for shade matching would be considered reliable. The Fleiss kappa statistical test was used to assess the reliability of each method. P ≤ 0.05 was considered statistically significant.
Using a light-correcting device significantly increased the reliability of the visual shade selection method. When compared to the shades recorded by the spectrophotometer (control), the use of a light-correcting device as an aid in visual shade selection showed more accurate and reliable results as compared to the visual shade selection without a light-correcting device (P < 0.05).
Light-correcting devices can assist in reliable shade selection and allow better communication with the dental laboratory technician to provide predictable esthetic results.
Accurate shade selection is one of the most critical aspects for predictable esthetic results in direct and indirect restorations. An accurate color reproduction for restorations and prostheses in the anterior esthetic zone can be challenging when patient expectations from such treatments are high due to the esthetic considerations.
The shade selection in dentistry uses standard visual shade tabs and advanced instrumental methods. The visual shade selection is a subjective process owing to the variables such as age, sex, type of scale used, clinical experience, degree of light exposure, source of light – artificial/natural, eye fatigue, clearness/opaqueness of teeth, tone of the clinic-neutral/bright, and physiological variables such as possible color deficiency that may lead to inaccuracies.
The advanced instrumental methods provide quantifiable, measurable shade values, decrease visual shade selection errors, and standardize the results.
The light-correcting device minimizes light interference and allows neutral clarity to assist in the visual method of shade selection by providing a standard light atmosphere. It is a hand-held lamp with the light-emitting diode-based technology with a light source simulating standard daylight (5500k).
Reliable existing evidence supports using a light-correcting source during tooth shade-matching.
The purpose of the present study was to evaluate the reliability of shade selection using the visual method with an economical light-correcting device (GDP True Light - Shade Matching Light) in clinical shade selection. The null hypothesis was that no significant improvement would be found in the reliability of shade matching using the light-correcting device.
The study followed an in vivo prospective experimental study. Two experienced observers (Dr. N and Dr. S) participated in the study. The study was approved by the Institutional Ethics Committee (IEC) of Christian Medical College and Hospital, Ludhiana (Ref BMHR/IECCMCL/0822-307/Apprvl-ICMR-STS-Proj/CDC). The study sample included 60 volunteers aged 18–25 with an intact maxillary right central incisor and no enamel pigmentation or anomaly. Each observer performed visual shade matching without a light-correcting device and later with a light-correcting device at the same time of the day and in the same dental office after 1 week. The shades were confirmed with the control value obtained using a spectrophotometer (VITA Easyshade
Advance 4.0). Each observer was blinded to the shade color selected by the other examiners.
Visual method – Shade matching was performed on the middle third of each participant's maxillary right central incisor by using a conventional shade guide (VITA Toothguide 3D-MASTER), first without the aid of a light-correcting device and then with the use of the light correcting device (GDP true light India), after 1 week
Instrumental method-Shade matching was performed using a spectrophotometer (VITA Easyshade advance 4.0)
(a and b) Visual shade selection with a light correcting device (GDP True Light). (a) Spectrophotometer-VITA Easyshade advance 4.0 in use to identify the shade of the tooth, (b) quantitative assessment of control shade value.
The data collected were subjected to the statistical analysis. The shade measured with the light-correcting device and without its use was compared with the control shade obtained by the spectrophotometer. The value closer to the control shade value was considered accurate, and the method used for shade matching would be considered reliable. The Fliess kappa statistical test for multiple measurements assessed method reliability. P ≤ 0.05 was considered statistically significant.
Sixty participants were enrolled in accounting for any possible exclusions and dropouts. The Fleiss' kappa statistical test was used to assess the reliability of each method. The result indicates that the recordings with light-correcting devices are statistically significantly closer to the control values (spectrophotometer) than the unaided visual shade selection values
The null hypothesis that using light-correcting devices would not improve shade selection was rejected. The present study results showed that the light-correcting device recordings were significantly associated with the spectrophotometric ones, as compared to the unaided visual recordings, indicating that using cost-effective light-correcting devices significantly improved the reliability of shade selection and provided similar results to the shade selection values obtained from the standard spectrophotometer device
In the present study, the kappa results showcased no significant associations between observers in the shade values recorded by both observers when using the visual alone or even with the light-correcting device method. However, compared with the spectrophotometer values of the shades recorded for each subject, which is considered the best objective instrumental technique for shade selection, using the light-correcting device as an aid showed more reliable and predictable shade matching (P < 0.05) for both observers. This result is similar to the results obtained in the study by Liberato et al.
The results of the present study have demonstrated that there was reduced inter-observer reliability for dental shade matching. The poor reduced inter-observer reliability may be due to the differences in expertise and eye fatigue among observers.
The previous study's findings suggest that although the existing light-correcting devices are reliable, as proven in the past, the cost of the devices makes it out of reach for most dental practitioners. The alternative indigenous economic light-correcting devices used in the present study provide a reliable option for shade selection with high efficacy during shade matching. Further evaluation of light-correcting devices compared with the existing light-correcting devices will help us know if there is any difference between the devices concerning shade-matching capabilities. While in the present study, both observers recorded with the visual, unaided method initially, and after a week, with the light-correcting device, there was a risk of carryover effect. This remains a study limitation, which could have been reduced by randomizing the order. Future research among a larger population and using multiple light-correcting devices against the new and improved generations of spectrophotometers and intraoral scanners can be done to evaluate the efficacy of light-correcting devices.
Light-correcting devices can aid in reliable shade selection and allow better shade communication with dental laboratory technicians, providing patients with better esthetic outcomes.