The incorporation of digital techniques has gained popularity in the fabrication of fixed dental prostheses (FDPs) over the last decade; however, limited evidence exists regarding the marginal and internal fit when using conventional versus digital impression techniques. This systematic review and meta-analysis aimed to compare the marginal and internal fit of tooth-supported multi-unit FDPs produced from conventional and digital impressions.
Materials and Methods:
A comprehensive search was conducted in electronic databases, including Cochrane Library, PubMed, and Scopus. A meta-analysis was conducted using the standardized mean differences (SMDs) to quantify the effect sizes.
Results:
Fourteen studies, three randomized controlled trials (RCTs) and 11 in vitro were included in the review, all complying with the inclusion criteria. The meta-analysis revealed that multi-unit FDPs fabricated using digital impressions generally exhibited improved marginal and internal fit compared with those produced using conventional impressions. In the RCT subgroup, digital impressions showed a trend toward improved marginal fit (SMD: −0.25; 95% confidence interval [CI]: −0.64–0.14) and statistically significant improvement for internal fit (SMD: −0.15; 95% CI: −0.55 to −0.24). In contrast, in vitro studies demonstrated statistically significant superiority of digital impressions for both marginal fit (SMD: −0.81; 95% CI: −1.06, −0.56) and internal fit (SMD: −0.52; 95% CI: −0.79 to −0.24).
Conclusion:
Although digitalized impressions demonstrated statistically superior marginal and internal fit compared with conventional impressions, the observed differences should be interpreted with caution. Most outcomes remained within clinically acceptable limits. Among the intraoral scanners, the Trios system showed a trend toward improved marginal fit.
Multiunit fixed dental prostheses (FDPs) are integral to contemporary dental practice and are routinely provided as the part of fixed prosthodontic treatments. While conventional impressions have long been used to fabricate these prostheses with consistent clinical success, they are not without limitations.[1] The challenges associated with the conventional technique include patient discomfort during impression-taking, difficulties in selecting appropriate trays, risk of dimensional changes due to delayed pouring, limited wettability of gypsum casts, and the potential for impression distortion during transport to the laboratory.[2] Such issues can contribute to inaccuracies in the marginal and internal fit of the final prosthesis.[3]
The integration of computer-aided design and computer-aided manufacturing technology has significantly enhanced the fabrication process of multi-unit FDPs. Digital impression techniques, employing laser or optical scanning, facilitate rapid and precise capture of both soft and hard tissues within the oral cavity, generating detailed digital impressions within minutes.[4] Two primary approaches to digital impression techniques exist: direct and indirect. The indirect method involves creating a gypsum cast from a conventional elastomeric impression, which is then scanned using a desktop scanner. In contrast, the direct method utilizes intraoral scanners (IOS) to capture the necessary anatomical structures directly from the patient’s mouth. The direct digital approach offers several advantages, including reduced chairside time and the elimination of conventional steps such as tray selection, impression material use, and cast pouring, thereby increasing efficiency and patient comfort.[5]
IOS systems employ various image acquisition technologies to optimize accuracy. For instance, the Sirona Cerec Bluecam system, introduced in 1987, uses structured blue light and requires a light dusting of powder to capture the images via principle of triangulation, where three straight beams of light intersect at one point. In contrast, newer powder-free systems like the Cerec Omnicam allow for full-arch or quadrant scanning using continuous image capture.[6] The iTero scanner utilizes confocal imaging with a strobe light and a probe for focus, eliminating the need for powder. Similarly, the Trios system (3Shape) employs ultrafast optical sectioning and confocal microscopy for accurate, powder-free imaging.[7] The Lava Chairside Oral Scanner (3M ESPE) differs by using active wavefront sampling with continuous video capture, although it requires a thin layer of titanium dioxide for optimal accuracy.[8]
The internal and marginal fit of multi-unit FDPs is critical to their clinical success. Holmes et al. defined internal fit as the perpendicular distance between the intaglio surface of the restoration and the prepared tooth surface.[9] Poor internal adaptation can hinder proper seating of the prostheses, while marginal discrepancies may lead to recurrent caries, gingival discoloration, and prosthesis failure.[10,11] Both conventional and digital impression techniques have demonstrated the ability to reproduce sufficient detail for accurate fit. Studies suggest that a marginal discrepancy of ≤120 μm and an internal discrepancy of ≤200 μm at the occlusal surface are clinically acceptable.[12,13] The efficacy of IOS has been previously proven in single-unit FDPs[14] and completely edentulous arches.[15]
A previous systematic review by Morsy et al.[16] concluded that zirconia FDPs fabricated using digital impressions exhibited superior marginal and internal fit compared to those made with conventional techniques. However, with the continuous advancement of IOS technology, newer generations are overcoming the limitations of earlier models. Therefore, the present systematic review aims to incorporate the most recent evidence to reassess and update the comparative evaluation of conventional and digital impressions in the fabrication of multi-unit FDPs.
The null hypothesis stated that there is no significant difference in the accuracy of the marginal and internal fit of prostheses fabricated using conventional and digital impression techniques, nor is there a difference in the accuracy of the various IOS available on the market.
MATERIALS AND METHODS
This systematic review was conducted following the Preferred Reporting Items of Systematic Reviews and Meta-analyses guidelines and has been registered on the International Prospective Register of Systematic Reviews (PROSPERO) CRD42023458713.
The research question was formulated using the PICO format: Patient (P): Patients requiring multi-unit FDPs, Intervention (I): Digital impressions, Comparison (C): Conventional impressions, and Outcome (O): Accuracy of marginal and internal fit. The primary question is digital impressions a feasible and accurate alternative to conventional impressions in achieving optimal marginal and internal fit in multi-unit FDPs? A secondary question was also explored: Do differences exist in scanning accuracy among the various IOSs currently available on the market?
Search strategy
A comprehensive literature search was conducted to identify studies comparing the marginal and internal fit of multi-unit FDPs fabricated using conventional and digital impression techniques. Electronic databases searched included the Cochrane Central Register of Controlled Trials, MEDLINE (PubMed), Scopus, and Web of Science. The search encompassed both controlled in vivo and in vitro studies published between 2013 and January 2025.
In addition to electronic searches, a manual search was performed in leading prosthodontic journals such as the International Journal of Prosthodontics, Journal of Prosthetic Dentistry, Journal of Esthetic and Restorative Dentistry, European Journal of Esthetic Dentistry, and Journal of Prosthodontics. Reference lists and citations of selected articles were also screened to identify any additional relevant studies. A combination of free-text keywords and Medical Subject Headings terms was used, employing Boolean operators to optimize search sensitivity and specificity [Table 1].
Search strategy
Eligibility criteria
The review included in vivo and in vitro studies that focused on the quantitative measurement of internal and marginal gaps in multi-unit FDPs fabricated from conventional and digital impressions and published in English. The exclusion criteria were article where direct comparison of digital and conventional impression was not done. Case reports, case series, and systematic reviews were excluded.
Initial screening of titles and abstracts identified through the electronic search was performed independently by two reviewers (G.S., A.S.) to determine eligibility. Articles were excluded based on abstract review; in cases of ambiguity, the full text was retrieved for further assessment. The full texts of all potentially relevant articles were obtained and evaluated by the reviewers based on the predefined inclusion criteria. Any disagreements between the two authors were resolved through the consensus with a third author (S.P.). Data extraction was performed for each qualified study, recording details such as author, year of publication, study type, sample size, number of units and region, impression system, marginal fit, and internal fit [Tables 2 and 3].
Characteristic of included in vitro studies
Characteristic of included randomized controlled trials
Risk of bias
Two reviewers (G.S., A.S.) independently assessed the risk of bias (ROB) and the quality of the included studies. The Cochrane collaboration tool was used to assess the ROB for randomized controlled trials (RCTs).[30] The studies were categorized under low ROB, unclear ROB, and high ROB.
The quality assessment tool for in vitro studies (QUIN tool) was used to evaluate the in vitro studies.[31] Each study was assessed based on 12 criteria [Table 4]. Scoring was as follows: 2 points for adequately specified criteria, 1 point for inadequately specified criteria, 0 points for unspecified criteria, and exclusion from calculation if not applicable. The total score for each study was computed and categorized as low (>70%), medium (50%–70%), or high ROB (<50%) using the formula: Final score = (Total score × 100)/(2 × number of applicable criteria).
Quality assessment tool for in vitro studies tool
Data analysis
The marginal and internal gap between the prostheses and the abutment was considered the primary outcome. Accuracy of different IOS was measured as the secondary outcome.
Extracted data were analyzed using a review manager software program RevMan 5.4.1 (Review Manager 5, Version 5.4. Cochrane Collaboration 2020; Copenhagen, Denmark)). Standardized mean difference (SMD) with 95% confidence interval (CI) was calculated for the effect size of each study as the outcome variables were continuous. The results for each impression technique were represented separately. The inverse variance-weighted method was used to estimate overall SMD. Due to high heterogeneity, sub-group analysis was conducted to evaluate the marginal and internal fit associated with the different IOS used in the study. Funnel plots of effect size and standard error were used to assess publication bias for both marginal and internal fit.
RESULTS
A total of 236 studies were identified through electronic searches (PubMed: 126, Cochrane: 26, and Web of Science: 78) and hand searches (n = 6). After removing 108 duplicate studies, 128 remained for screening based on title and abstract, leading to the exclusion of 96 studies. Subsequently, 32 full-text articles were assessed for eligibility, with 18 being excluded due to lack of comparison with conventional impressions (n = 8), qualitative analysis only (n = 5), absence of internal fit discrepancy values (n = 3), and case report format (n = 2). Ultimately, 14 studies were included in the review, comprising 11 in vitro studies[13,17-26] and 3 RCTs.[27-29] [Figure 1].
Preferred Reporting Items of Systematic Reviews and Meta-analyses flowchart for literature search.
A summary of the characteristics of the included studies is depicted in Tables 2 and 3. Ten studies employed the impression replica technique to evaluate discrepancies. In most of these studies, polyvinyl siloxane was used as the replica material; however, Moustapha et al.[20] utilized polyether for the replica technique, which may have contributed to methodological variability due to differences in material properties. Svanborg et al.[24] used the triple scan technique; likewise, a study by Bandiaky et al.[17] used a combination of impression replica along with micro computed tomography, Kocaağaoğlu et al.[19] used direct view technique and Shembesh et al.[23] used optical comparator. The observed heterogeneity may be partly attributed to variations in fit measurement techniques across studies, which can affect the accuracy and comparability of reported outcomes and, consequently, influence the pooled estimates.
Risk of bias assessment
The ROB results for RCTs are depicted in the Figure 2. All the RCTs manifested low risk in selection, detection, attrition, and reporting bias. There was an unclear risk of performance bias as there was no mention of blinding of participants or operators in all the three RCTs,[27-29] which limits the certainty of evidence. The ROB analysis for the in vitro studies using the QUIN tool had a final score above 70%, depicting a low ROB in these studies [Figure 3].
Risk of bias assessment of included studies using the cochrane collaboration tool.
Quality Assessment of in vitro studies using QUIN tool.
Assessment of marginal fit of in vitro studies
A statistically significant difference for marginal fit was found encompassing in vitro studies favoring the digital impressions over conventional impressions with SMD: −0.81; (95% CI: −1.06, −0.56; P < 0.00001). The meta-analysis depicting the marginal fit is shown in Figure 4. However, the substantial heterogeneity (I2 = 77%) suggests variability among studies, which may be due to the differences in study design, IOS type, or measurement techniques.
Forest plot of comparison of in vitro studies showing marginal fit as standardized mean difference.
Assessment of marginal fit of randomized controlled trial
An improved marginal fit was found favoring the digital impressions compared with conventional impressions (SMD: −0.25; (95% CI: −0.64, 0.14; P < 0.00001). The meta-analysis depicting the marginal fit is shown in Figure 5. However, the I2 value 0% is suggestive of no heterogeneity among the studies.
Forest plot of comparison of randomized controlled trial showing marginal fit as standardized mean difference.
Assessment of internal fit of in vitro studies
A statistically significant difference for the internal fit was found favoring digital impressions (SMD −0.52; 95% CI: −0.79, −0.24; P < 0.00001). I2 = 52% denotes lesser heterogeneity, indicating lesser variability among studies. The meta-analysis for internal fit is depicted in Figure 6.
Forest plot of comparison of in vitro studies showing internal fit as standardized mean difference.
Assessment of internal fit of randomized controlled trial
A significant difference for the internal fit was found favoring digital impressions SMD −0.15; (95% CI: −0.55, 0.24; P < 0.00001). I2 = 0% suggestive of no heterogeneity among the studies. The meta-analysis for internal fit is depicted in Figure 7.
Forest plot of comparison of randomized controlled trial showing internal fit as standardized mean difference.
A subgroup analysis by IOS type was performed by categorizing the studies based on the IOS used. Based on the subgroup analysis, the studies appear to include different IOS types such as Trios, Cerec, iTero, CS3600, and Lava. Total SMD for marginal fit: −0.78 (95% CI: −1.05–0.52) and for internal fit −0.50 (95% CI: −0.81 to −0.19) which indicates that digital impressions significantly outperform conventional impressions. Trios (3Shape) shows the strongest effect (−0.91 SMD), favoring digital impressions significantly with lowest heterogeneity (I2 = 14%) suggesting more consistent results. The results of the sub-group analysis did not reveal significant differences in internal fit. Cerec and iTero also favor digital impressions, but with some variability. Lava scanners do not show a significant difference, suggesting inconsistent performance. Other scanners CS3600 also favor digital impressions with low variability [Figures 8 and 9].
Subgroup analysis of comparison of in vitro studies showing marginal fit as standardized mean difference.
Subgroup analysis of comparison of in vitro studies showing internal fit as standardized mean difference.
The funnel plot for marginal fit shows the studies are clustered more on the left-hand side (negative SMD values), with fewer studies on the right. This asymmetry suggests potential publication bias or selective reporting, as studies favoring digital impressions (negative SMD) are more prevalent. While publication bias may slightly inflate effect estimates, the consistency and reproducibility of findings across multiple independent studies underscore the clinical advantage of digital workflows [Figure 10]. The funnel plot for internal fit shows no major asymmetry, indicating a reduced risk of publication bias. This strengthens the conclusion that findings on internal fit are more robust and less influenced by selective reporting [Figure 11]. Overall, these results suggest that digital impressions offer a predictable and efficient alternative to conventional techniques, with potential benefits including improved fit accuracy, reduced chairside adjustments, and enhanced workflow efficiency, thereby supporting their broader adoption in modern prosthodontic practice.
Funnel plot depicting publication bias for marginal fit.
Funnel plot depicting publication bias for internal fit.
DISCUSSION
This systematic review unequivocally supports the superiority of digital over conventional impression techniques, clearly rejecting the null hypothesis. The meta-analysis results revealed a statistically significant difference in both marginal and internal fit when using digital impressions as compared to conventional impression. The results are contradictory to finding of Moustapha et al.[20] wherein he reported better internal fit with conventional impressions (104 μ) than with digital impressions (115.6 μ) Similarly, in the study by Benic et al.,[28] internal fit achieved through conventional impressions (127.5 μ) was better than that of Lava (140 μ) and Cerec (131.8 μ).
Although all the studies included in our review demonstrated an acceptable marginal fit (i.e., 120 μ or less) according to McLean and von Fraunhofer’s[12] criteria in both the digital and conventional groups, however, our studies consistently showed acceptable internal discrepancies within the range of 100–200 μ.
No direct correlation could be established between the impression material used for the conventional impression or between the number of units in FDPs and the marginal or internal fit. Similarly, the studies included in the review did not establish a precise correlation between variables such as cement spacer, region of edentulousness, and the material of prostheses with the observed discrepancy.
Considering the substantial statistical heterogeneity, we opted for a subgroup analysis to compare the accuracy of various IOS used in the studies. Trios IOS demonstrated consistent results with lesser heterogeneity thus rejecting the second null hypothesis. Studies by Amornvit et al.[32] and Renne et al.[32,33] concluded that the Trios series depicted the best results consistent with our study’s results. The observed heterogeneities in our review are likely attributed to the diverse generations of IOS used in the included studies and the inclusion of studies which scanned different regions of the mouth. Despite this variability, the overall pooled estimates consistently favored digital impressions, suggesting that the digital workflow offers comparable or superior fit accuracy to conventional methods. Notably, newer generation IOS, equipped with advanced software, tends to yield lower discrepancy values for marginal fit.
Such differences in the accuracy of scanners could be attributed to their different scanning strategies. There is a considerable possibility of errors while scanning with IOS, as it captures approximately 1200 images during the scanning process.[34,35] Errors may arise from the superimposition of these images during scanning and processing. These errors are more common in anterior teeth due to their steep inclines and smaller surface area. Additional errors can occur during computer processing, often due to filter algorithms and calibration issues.[36,37]
Previous studies reported that different IOSs varied in scanning accuracy.[5,38] No conclusion has been reached regarding the superiority of a certain IOS from the current subgroup analysis because few studies were included, and heterogeneity was high. However, the Trios scanner had the best performance in the digital group for marginal fit with 14% heterogeneity and SMD of −0.91, consistent with a previous review by Morsy et al.[16]
The accuracy of IOS is also contingent on various factors, including blood and moisture control, gingival retraction, and the position of the marginal finish line on the tooth. Notably, the operator’s skill during scanning also plays a crucial role in determining accuracy.[39,40]
The limitations of this study were inclusion of only a few clinical studies, with the majority being in vitro, where frameworks were fabricated and tested under controlled laboratory conditions. This may not fully represent in vivo scenarios, slightly reducing clinical relevance. In future more in vivo studies with a long-term follow-up are needed to assess the accuracy of the fit of the prostheses. Although statistically significant differences were observed, the clinical relevance of these findings remains uncertain, as the magnitude of the effect may fall within clinically acceptable limits.
CONCLUSION
As the certainty of evidence is limited, the conclusions should be interpreted with caution.
The Digital Impression technique has demonstrated better marginal and internal fit than the conventional impression technique
The Trios IOS has depicted an enhanced marginal fit compared to the rest.
Financial support and sponsorship
Nil.
Conflicts of interest
The authors of this manuscript declare that they have no conflicts of interest, real or perceived, financial or non-financial in this article.
REFERENCESD'AmbrosioF, GiordanoF, SangiovanniG, Di PaloMP, AmatoM. Conventional versus digital dental impression techniques:What is the future?An umbrella review. Prosthesis2023;5:851–75.HackerT, HeydeckeG, ReissmannDR. Impact of procedures during prosthodontic treatment on patients'perceived burdens. J Dent2015;43:51–7.SeelbachP, BrueckelC, WöstmannB. Accuracy of digital and conventional impression techniques and workflow. Clin Oral Investig2013;17:1759–64.BaroudiK, IbraheemSN. Assessment of chair-side computer-aided design and computer-aided manufacturing restorations:A review of the literature. J Int Oral Health2015;7:96–104.ShahN, ThakurM, GillS, ShettyO, AlqahtaniNM, Al-QarniMA, et al. Validation of digital impressions'accuracy obtained using intraoral and extraoral scanners:A systematic review. J Clin Med2023;12:5833.Ting-ShuS, JianS. Intraoral digital impression technique:A review. J Prosthodont2015;24:313–21.LeeKM. Comparison of two intraoral scanners based on three-dimensional surface analysis. Prog Orthod2018;19:6.van der MeerWJ, AndriessenFS, WismeijerD, RenY. Application of intra-oral dental scanners in the digital workflow of implantology. PLoS One2012;7:e43312.HolmesJR, BayneSC, HollandGA, SulikWD. Considerations in measurement of marginal fit. J Prosthet Dent1989;62:405–8.FeltonDA, KanoyBE, BayneSC, WirthmanGP. Effect of in vivo crown margin discrepancies on periodontal health. J Prosthet Dent1991;65:357–64.HasanzadeM, AminikhahM, AfrashtehfarKI, AlikhasiM. Marginal and internal adaptation of single crowns and fixed dental prostheses by using digital and conventional workflows:A systematic review and meta-analysis. J Prosthet Dent2021;126:360–8.McLeanJW, von FraunhoferJA. The estimation of cement film thickness by an in vivo technique. Br Dent J1971;131:107–11.ArezoobakhshA, ShayeghSS, Jamali GhomiA, HakimanehSM. Comparison of marginal and internal fit of 3-unit zirconia frameworks fabricated with CAD-CAM technology using direct and indirect digital scans. J Prosthet Dent2020;123:105–12.ManishaJ, SrivastavaG, DasSS, TabarakN, ChoudhuryGK. Accuracy of single-unit ceramic crown fabrication after digital versus conventional impressions:A systematic review and meta-analysis. J Indian Prosthodont Soc2023;23:105–11.SrivastavaG, PadhiarySK, MohantyN, Molinero-MourelleP, ChebibN. Accuracy of intraoral scanner for recording completely edentulous arches-a systematic review. Dent J (Basel)2023;11:241.MorsyN, El KatebM, AzerA, FathallaS. Fit of zirconia fixed partial dentures fabricated from conventional impressions and digital scans:A systematic review and meta-analysis. J Prosthet Dent2023;130:28–34.BandiakyON, ClouetR, Le BarsP, SoueidanA, Le GuehennecL. Marginal and internal fit of five-unit zirconia-based fixed dental prostheses fabricated with digital scans and conventional impressions:A comparative in vitro study. J Prosthodont2023;32:846–53.UlucIG, GuncuMB, AktasG, TurkyilmazI. Comparison of marginal and internal fit of 5-unit zirconia fixed dental prostheses fabricated with CAD/CAM technology using direct and indirect digital scans. J Dent Sci2022;17:63–9.KocaağaoğluH, AlbayrakH, Cinel SahinS, GürbulakAG. Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques. J Adv Prosthodont2019;11:262–70.MoustaphaG, AzzamK, AlShwaimiE, SilwadiM, FerrariM, SalamehZ. Evaluation of the fit of zirconia three-unit fixed partial dentures fabricated by different impression techniques. J Investig Clin Dent2019;10:e12413.KimWK, KimS. Effect of number of pontics and impression technique on the accuracy of four-unit monolithic zirconia fixed dental prostheses. J Prosthet Dent2018;119:860.e1–7.SuTS, SunJ. Comparison of marginal and internal fit of 3-unit ceramic fixed dental prostheses made with either a conventional or digital impression. J Prosthet Dent2016;116:362–7.ShembeshM, AliA, FinkelmanM, WeberHP, ZandparsaR. An in vitro comparison of the marginal adaptation accuracy of CAD/CAM restorations using different impression systems. J Prosthodont2017;26:581–6.SvanborgP, SkjervenH, CarlssonP, EliassonA, KarlssonS, OrtorpA. Marginal and internal fit of cobalt-chromium fixed dental prostheses generated from digital and conventional impressions. Int J Dent2014;2014:534382.KeulC, StawarczykB, ErdeltKJ, BeuerF, EdelhoffD, GüthJF. Fit of 4-unit FDPs made of zirconia and CoCr-alloy after chairside and labside digitalization-a laboratory study. Dent Mater2014;30:400–7.Almeida e SilvaJS, ErdeltK, EdelhoffD, AraújoÉ, StimmelmayrM, VieiraLC, et al. Marginal and internal fit of four-unit zirconia fixed dental prostheses based on digital and conventional impression techniques. Clin Oral Investig2014;18:515–23.MorsyN, El KatebM, AzerA, FathallaS. Fit of monolithic multilayer zirconia fixed partial dentures fabricated by conventional versus digital impression:A clinical and laboratory investigations. Clin Oral Investig2021;25:5363–73.BenicGI, SailerI, ZeltnerM, GütermannJN, ÖzcanM, MühlemannS. Randomized controlled clinical trial of digital and conventional workflows for the fabrication of zirconia-ceramic fixed partial dentures. Part III:Marginal and internal fit. J Prosthet Dent2019;121:426–31.AhrbergD, LauerHC, AhrbergM, WeiglP. Evaluation of fit and efficiency of CAD/CAM fabricated all-ceramic restorations based on direct and indirect digitalization:A double-blinded, randomized clinical trial. Clin Oral Investig2016;20:291–300.HigginsJP, AltmanDG, GøtzschePC, JüniP, MoherD, OxmanAD, et al. The Cochrane collaboration's tool for assessing risk of bias in randomised trials. BMJ2011;343:d5928.ShethVH, ShahNP, JainR, BhanushaliN, BhatnagarV. Development and validation of a risk-of-bias tool for assessing in vitro studies conducted in dentistry:The QUIN. J Prosthet Dent2024;131:1038–42.AmornvitP, RokayaD, SanohkanS. Comparison of accuracy of current ten intraoral scanners. Biomed Res Int2021;2021:2673040.RenneW, LudlowM, FrymlJ, SchurchZ, MennitoA, KesslerR, et al. Evaluation of the accuracy of 7 digital scanners:An in vitro analysis based on 3-dimensional comparisons. J Prosthet Dent2017;118:36–42.TakeuchiY, KoizumiH, FuruchiM, SatoY, OhkuboC, MatsumuraH. Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses. J Oral Sci2018;60:1–7.RudolphH, SalmenH, MoldanM, KuhnK, SichwardtV, WöstmannB, et al. Accuracy of intraoral and extraoral digital data acquisition for dental restorations. J Appl Oral Sci2016;24:85–94.EnderA, MehlA. Accuracy of complete-arch dental impressions:A new method of measuring trueness and precision. J Prosthet Dent2013;109:121–8.MehlA, EnderA, MörmannW, AttinT. Accuracy testing of a new intraoral 3D camera. Int J Comput Dent2009;12:11–28.CiocanLT, VasilescuVG, RăuţăSA, PanteaM, PiţuruSM, ImreM. Comparative analysis of four different intraoral scanners:An in vitro study. Diagnostics (Basel)2024;14:1453.ResendeCC, BarbosaTA, MouraGF, TavaresLD, RizzanteFA, GeorgeFM, et al. Influence of operator experience, scanner type, and scan size on 3D scans. J Prosthet Dent2021;125:294–9.TabarakN, SrivastavaG, PadhiarySK, ManishaJ, ChoudhuryGK. Zirconia-ceramic versus metal-ceramic implant-supported multiunit fixed dental prostheses:A systematic review and meta-analysis. Dent Res J (Isfahan)2024;21:5.